2000
DOI: 10.1002/1521-4109(200010)12:15<1220::aid-elan1220>3.0.co;2-2
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Roxarsone Using Carbon Paste and Amberlite LA2 Modified Carbon Paste Electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
2
0

Year Published

2002
2002
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 23 publications
0
2
0
Order By: Relevance
“…Extracts have been analyzed using a diverse set of analytical techniques (Table 3), including atomic absorption spectroscopy (AAS) (Frahm et al, 1975;Liebhardt, 1976;George et al, 1982;Nachman et al, 2008), hydride generation with atomic fluorescence spectrometry (HG-AFS) (Wang et al, 2006), gas chromatography with mass spectrometry (GC-MS) (Roerdink and Aldstadt, 2004), and high performance liquid chromatography (HPLC) coupled to UV detectors (Sapp and Davidson, 1993;Croteau et al, 1994;Chen et al, 2011;Chen and Huang, 2012), inductively coupled plasma mass spectrometry (ICP-MS) (Dean et al, 1994;Pergantis et al, 1995Pergantis et al, , 1997aJackson and Bertsch, 2001;Wang et al, 2010), or electrospray ionization mass spectrometry (ESI-MS) (Pergantis et al, 1997b;Wang et al, 2011), among others (Morrison, 1968;George and Morrison, 1971;Ahamad et al, 2000;Yao et al, 2013b).…”
Section: Analytical Measurement Of Organoarsenicalsmentioning
confidence: 99%
See 1 more Smart Citation
“…Extracts have been analyzed using a diverse set of analytical techniques (Table 3), including atomic absorption spectroscopy (AAS) (Frahm et al, 1975;Liebhardt, 1976;George et al, 1982;Nachman et al, 2008), hydride generation with atomic fluorescence spectrometry (HG-AFS) (Wang et al, 2006), gas chromatography with mass spectrometry (GC-MS) (Roerdink and Aldstadt, 2004), and high performance liquid chromatography (HPLC) coupled to UV detectors (Sapp and Davidson, 1993;Croteau et al, 1994;Chen et al, 2011;Chen and Huang, 2012), inductively coupled plasma mass spectrometry (ICP-MS) (Dean et al, 1994;Pergantis et al, 1995Pergantis et al, , 1997aJackson and Bertsch, 2001;Wang et al, 2010), or electrospray ionization mass spectrometry (ESI-MS) (Pergantis et al, 1997b;Wang et al, 2011), among others (Morrison, 1968;George and Morrison, 1971;Ahamad et al, 2000;Yao et al, 2013b).…”
Section: Analytical Measurement Of Organoarsenicalsmentioning
confidence: 99%
“…Advanced methods developed after 1990 use liquid chromatography coupled to various detectors that allow for low limits of detection: 260 μg/L for roxarsone-selective electrodes (Ahamad et al, 2000), 0.05-25 μg/L for ICP-MS (Dean et al, 1994;Jackson and Bertsch, 2001), and 0.15 μg/L for ESI-MS (Pergantis et al, 1997b). HPLC-ICP- MS methods have been employed due to low detection limits in complex sample matrices (Ogra, 2012); however, these methods are of limited use when unknown, or unidentified, arsenic-containing species are present in solution.…”
Section: Analytical Measurement Of Organoarsenicalsmentioning
confidence: 99%
“…The limits of detection (LOD) and quantification (LOQ) calculated as LOD = 3SD a /b and LOQ = 10SD a /b [43] were 9.6 × 10 −11 and 3.2 × 10 −10 M, respectively. Table 3 compares the analytical parameters of the developed procedure with those previously described in the literature for other voltammetric sensors [10][11][12][13][14][15][16][17][18][19][20][21][22][23]. As can be seen, we obtained a very wide range of linearity of the calibration curve and additionally the lowest limit of detection in comparison to those that had been described in the literature thus far.…”
Section: Selectivity and Analytical Characteristicsmentioning
confidence: 56%
“…Many of them are chromatographic methods such as high-performance liquid chromatography (HPLC) and gas chromatography (GC) [8,9]. Many voltammetric procedures for ROX determination have been presented in the literature [10][11][12][13][14][15][16][17][18][19][20][21][22][23]. Voltammetric methods are Materials 2023, 16, 5420 2 of 17 characterized by very high sensitivity.…”
Section: Introductionmentioning
confidence: 99%