2013
DOI: 10.46770/as.2013.01.002
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Rare Earth Elements, Yttrium, Thorium, and Other Trace Elements in Monazite Samples by Inductively Coupled Plasma Mass Spectrometry

Abstract: The analytical results obtained by both methods were found to compare well with each other as well as with the results obtained by ICP-OES in the case of REEs, uranium, and thorium. However, in the case of zirconium, quantitative recoveries were obtained only with the fluoride fusion method. Though international monazite reference materials are available, certified or even probable values are not available for all the constituent elements. A certified monazite reference material, BGS: IGS-36 (British Geologica… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 9 publications
0
3
0
Order By: Relevance
“…The analytical precision was better than 0.05 μmol/L for NO 3 + NO 2 ‐N, 0.02 μmol/L for PO 4 ‐P, and 1 μmol/L for Si(OH) 4 . All REEs samples were pre‐concentrated using NOBIAS PA1 (Q. Liu et al., 2022; Takata et al., 2009) and analyzed with an ICP‐MS (Agilent 7700×, USA) equipped with an Apex IR desolvating nebulizer (ESI, USA). Lutetium was utilized as the internal standard for quantifying the REE recoveries during pre‐concentration (Text S1 in Supporting Information ), which were higher than 95%.…”
Section: Methodsmentioning
confidence: 99%
“…The analytical precision was better than 0.05 μmol/L for NO 3 + NO 2 ‐N, 0.02 μmol/L for PO 4 ‐P, and 1 μmol/L for Si(OH) 4 . All REEs samples were pre‐concentrated using NOBIAS PA1 (Q. Liu et al., 2022; Takata et al., 2009) and analyzed with an ICP‐MS (Agilent 7700×, USA) equipped with an Apex IR desolvating nebulizer (ESI, USA). Lutetium was utilized as the internal standard for quantifying the REE recoveries during pre‐concentration (Text S1 in Supporting Information ), which were higher than 95%.…”
Section: Methodsmentioning
confidence: 99%
“…ICP-MS provides a more powerful and accurate determination of rare earth elements and also the trace elements present in ppm-level. Padmasubashini and Nandakishore determine rare earth and radioactive elements in ilmenite by ICP-MS (Padmasubashini and Nandakishore 2013). Rajendran et al determine rare earth elements of Indian coastal monazites using ICP-MS (Rajendran et al 2008).…”
Section: Methodsmentioning
confidence: 99%
“…In coastal deposits, heavy minerals enrichment occurs by winds, waves and currents. Zircon makes up a relatively small percentage of the economic heavy minerals in most deposits and is produced as a by product of heavy-In recent years, Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) [11] trace element determinations, especially for REEs and have been applied to their determination in geological materials like rocks, ores, minerals, and concentrates [14]. The goal of the present work is a study for the determination of a trace amount of zirconium and hafnium in the presence of each other in the Egyptian beach black sand monazite which was selected and physically separated [15].…”
Section: Monazitementioning
confidence: 99%