2014
DOI: 10.1002/prep.201300147
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Primary Amine Content in Bonding Agent Used in Composite Solid Propellants

Abstract: The primary amine content in tetraethylenepentamine (TEPA) and TEPAN, a bonding agent used in composite solid propellants, was determined by near infrared (NIR) spectroscopy and the results were compared to those obtained by potentiometry. The band at 4930 cm−1, which showed to be influenced only by primary amine groups, was chosen as the analytical band. The calibration curves based on isopropylamine (IPA) and isopropylamine/dibutylamine (IPA/DBA) mixtures proved to be suitable for determining the NH2 content… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 61 publications
(98 reference statements)
0
6
0
1
Order By: Relevance
“…The peaks characteristic for neutral form disappeared and only peaks of triethylamine at ~1400, 1700–1800 nm were observed [13]. …”
Section: Resultsmentioning
confidence: 99%
“…The peaks characteristic for neutral form disappeared and only peaks of triethylamine at ~1400, 1700–1800 nm were observed [13]. …”
Section: Resultsmentioning
confidence: 99%
“…The functional groups (such as -CONH) can induce the -NO 2 of nitramine to form hydrogen bonds [9][10][11][12]. The sp 2 hybridized orbital of boron atoms is easy to form stable complexes with electron donors in nitramine. These factors are favorable for the accumulation of borate bonding agents on the surface of nitramine solid particles and the formation of stable coating.…”
Section: Borate Ester Bonding Agentsmentioning
confidence: 99%
“…Solid propellants are composite materials which consist of solid fillers (such as oxidant and metallic fuel) and polymer binders [1][2][3]. Increasing the level of energy is the eternal theme of solid propellant development.…”
Section: Introductionmentioning
confidence: 99%
“…Sendo assim, para cada amostra, foram analisadas cinco (5) alíquotas e determinada a mediana dos valores das respectivas absorvâncias, prática usual em textos de espectroscopia no infravermelho [14] , conforme citado e adotada em diversas publicações do grupo, incluindo as recentes, aplicados a diferentes materiais e determinações, mostrando que é útil e adequada, para diversos estudos [15,16] . O desvio médio padrão( ) µ σ .da mediana foi calculado, segundo a Equação 1:…”
Section: Equações Usadas Na Metodologia Para O Cálculo Dos Desviosunclassified