Determination of Precise 135Cs/137Cs Ratio in Environmental Samples Using Sector Field Inductively Coupled Plasma Mass Spectrometry

Abstract: Recent advances in sector field inductively coupled plasma mass spectrometry (ICP-SFMS) have led to significant sensitivity enhancements that expand the range of radionuclides measurable by ICP-MS. The increasing capability and performance of modern ICP-MS now allows analysis of medium-lived radionuclides previously undertaken using radiometric methods. A new generation ICP-SFMS was configured to achieve sensitivities up to 80,000 counts per second for a 1 ng/L (133)Cs solution, providing a detection limit of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
58
2

Year Published

2015
2015
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 39 publications
(60 citation statements)
references
References 40 publications
0
58
2
Order By: Relevance
“…It is widely accepted that using ICP-MS for determining 135 Cs and 137 Cs presents a great challenge due to serious isobaric interferences ( 135 Ba þ and 137 Ba þ ), the peak tailing effect of 133 Cs [14,18,25,29] [25,30]. In order to separate Cs from the matrix, we applied AMP ((NH 4 ) 3 PO 4 Á 12MoO 3 Á 3H 2 O) to pre-concentrate Cs because of its extremely high selectivity for Cs [31].…”
Section: Cs Isotope Analysismentioning
confidence: 99%
“…It is widely accepted that using ICP-MS for determining 135 Cs and 137 Cs presents a great challenge due to serious isobaric interferences ( 135 Ba þ and 137 Ba þ ), the peak tailing effect of 133 Cs [14,18,25,29] [25,30]. In order to separate Cs from the matrix, we applied AMP ((NH 4 ) 3 PO 4 Á 12MoO 3 Á 3H 2 O) to pre-concentrate Cs because of its extremely high selectivity for Cs [31].…”
Section: Cs Isotope Analysismentioning
confidence: 99%
“…51,117 Similarly, whilst 135 Cs and 137 Cs have been recovered by acid leaching for a range of sample matrices, it was proven that complete recovery in clay-rich sediments was only achievable using lithium borate fusion. 1 Additionally, certain radionuclides ( 99 Tc and 129 I) suffer from losses due to volatility, which must be considered during sample preparation. A summary of sample digestion methods available for radionuclides has recently been published.…”
Section: Sample Preparationmentioning
confidence: 99%
“…For mass spectrometric measurement, Cs separation has commonly been achieved using ammonium molybdophosphate (AMP) followed by anion exchange and/or cation exchange chromatography, most commonly Dowex AG1 and Dowex AG50W (both Bio-Rad, USA), respectively. 1,195,197,198,200,202 Other techniques include extraction chromatography using calixarenes, 203 and potassium nickel hexacyanoferrate (KNiFC). 200 Barium-138 (natural abundance 71.7%) has been used to assess the effectiveness of separation at masses 135 and 137, however any interference correction will reduce the accuracy of 135 Cs/ 137 Cs values.…”
Section: Caesium 135 and 137mentioning
confidence: 99%
“…Mass spectrometry techniques ICP-MS, AMS, RIMS, TIMS, and SIMS have been used for the determination of 135 Cs and 137 Cs (Taylor et al, 2008;Eliades et al, 2013;H€ olgye et al, 2004;Ohno and Muramatsu, 2014;Chao and Tseng, 1996;Zheng et al, 2014a,b;Russell et al, 2014;Suseno and Prihatiningsih, 2014;Hancock et al, 2014;Pibida et al, 2001Pibida et al, , 2004Moreno et al, 1999;Lee et al, 1993;Edgington et al, 1991;Thakur et al, 2013). 137 Cs is a short-lived radionuclide (30.07 years).…”
Section: Introductionmentioning