1990
DOI: 10.1016/0198-0149(90)90034-s
|View full text |Cite
|
Sign up to set email alerts
|

Determination of organic carbon and nitrogen in marine sediments using the Carlo Erba NA-1500 analyzer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
354
2
6

Year Published

1999
1999
2018
2018

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 734 publications
(365 citation statements)
references
References 3 publications
3
354
2
6
Order By: Relevance
“…Sediment samples were weighed into tin cups for nitrogen analysis. For the analysis of carbon, samples were weighed into aluminium cups and were subsequently sequentially acidified using sulphurous acid to remove any mineral carbonates (Verardo et al 1990). Samples were analysed for nitrogen and carbon contents, δ 15 N and δ 13 C, using a Carlo Erba NA1500 CNS analyser interfaced via a Conflo II to a Finnigan Mat Delta S isotope-ratio mass spectrometer operating in the continuous-flow mode.…”
Section: Methodsmentioning
confidence: 99%
“…Sediment samples were weighed into tin cups for nitrogen analysis. For the analysis of carbon, samples were weighed into aluminium cups and were subsequently sequentially acidified using sulphurous acid to remove any mineral carbonates (Verardo et al 1990). Samples were analysed for nitrogen and carbon contents, δ 15 N and δ 13 C, using a Carlo Erba NA1500 CNS analyser interfaced via a Conflo II to a Finnigan Mat Delta S isotope-ratio mass spectrometer operating in the continuous-flow mode.…”
Section: Methodsmentioning
confidence: 99%
“…Weighed samples were then acidified in-situ with 6% sulfurous acid to remove carbonate phases (Verardo, Froelich, & McIntyre, 1990). Each sediment sample was analyzed for total organic carbon (TOC) using a Carlo Erba NA-1500 elemental analyzer.…”
Section: Core Sampling and Total Organic Carbon (Toc) Analysismentioning
confidence: 99%
“…Filters were folded, placed in plastic collection bags and stored at À 20 1C. POC and PN content of the suspended particulate matter on acid-fumed filters (Hedges and Stern, 1984) were determined at the University of California, Davis using a Carlo Erba NA-1500 Elemental Analyzer system (CE Elantech, Lakewood, NJ, USA) as described by (Verardo et al, 1990). For each day that samples were collected, we determined several basic physical characteristics of the Columbia River coastal margin.…”
Section: Methodsmentioning
confidence: 99%