2001
DOI: 10.1016/s0378-4347(01)00386-3
|View full text |Cite
|
Sign up to set email alerts
|

Determination of LSD and its metabolites in human biological fluids by high-performance liquid chromatography with electrospray tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
47
0
3

Year Published

2004
2004
2017
2017

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 56 publications
(52 citation statements)
references
References 20 publications
1
47
0
3
Order By: Relevance
“…at m/z 309 and [MH-C 2 H 5 ] +. at m/z 293 but neither were observed in ESI and CID conditions in a triple quadrupole [6,10]. To detect further fragmentation pathways, MS 3 experiments were also performed on CID-generated ion species at m/z 281 and 223 (see Table 1) at tickle voltage of 28 and 35%, respectively.…”
Section: Ms/msmentioning
confidence: 99%
See 2 more Smart Citations
“…at m/z 309 and [MH-C 2 H 5 ] +. at m/z 293 but neither were observed in ESI and CID conditions in a triple quadrupole [6,10]. To detect further fragmentation pathways, MS 3 experiments were also performed on CID-generated ion species at m/z 281 and 223 (see Table 1) at tickle voltage of 28 and 35%, respectively.…”
Section: Ms/msmentioning
confidence: 99%
“…Of the various analytical approaches which have been proposed in the last decade, a leading role has been played by those employing multiple mass spectrometry (MS/MS) features which allow the mise au point of specific and sensitive methods based either on gas chromatographymultiple mass spectrometry (GC-MS/MS) or liquid chromatography-multiple mass spectrometry (LC-MS/MS) either on triple quadrupole mass spectrometers or on single quadrupoles (by in-source collisional experiments) [6][7][8][9][10][11][12]. Poch et al were the first to propose an LC-MS/MS method in an ion trap (IT) equipped with an atmospheric-pressure chemical ionization (APCI) interface [13] for the determination of O-H-LSD; that method proved suitable for the analysis of the polar metabolite but lacked in specificity for LSD.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Within-and between-day coefficients of variation were 3.5% and 4.0%, respectively, and the extraction recovery was 91%. Canezin et al [73] have developed an HPLC procedure with ESI-MS/MS detection for both urine and blood and validated it for LSD and iso-LSD determination. A one-step liquid-liquid extraction on 1 mL blood or urine was used.…”
Section: Lsdmentioning
confidence: 99%
“…Conventional analytical methods used in the last decade consist of liquid chroma- tographic separations with an MS detection following a sample pretreatment step [2]. LSD has been extracted by an alkaline liquid -liquid extraction from urine, blood [3,4], and recently from vitreous humor [5]. SPE was also used for urine samples to provide cleaner extracts with a lowest organic solvent consumption [6,7].…”
Section: Introductionmentioning
confidence: 99%