2002
DOI: 10.1039/b110388a
|View full text |Cite
|
Sign up to set email alerts
|

Determination of lead and cadmium in organic solutions by electrothermal atomic absorption spectrometry with a transverse heated filter atomizer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
23
2
1

Year Published

2002
2002
2010
2010

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 18 publications
(27 citation statements)
references
References 23 publications
1
23
2
1
Order By: Relevance
“…[5,7,16,21,27,28,33,34,36,40,41,43,50,56,58,61,[68][69][70]73,74,77,[79][80][81]83,85,87,88,90,[92][93][94][95][97][98][99]102,114,115,121,125,127,128,131,134,135,144,148,149,152,154,1...…”
Section: Spectrometer Improvementsmentioning
confidence: 99%
“…[5,7,16,21,27,28,33,34,36,40,41,43,50,56,58,61,[68][69][70]73,74,77,[79][80][81]83,85,87,88,90,[92][93][94][95][97][98][99]102,114,115,121,125,127,128,131,134,135,144,148,149,152,154,1...…”
Section: Spectrometer Improvementsmentioning
confidence: 99%
“…Optical arrangement of the line source based AA instruments employed earlier with filter atomization [15][16][17][18][19][20][21][22][23][24] place rigorous restrictions on both parameters. Light losses due to reduced aperture of the light beam and intense radiation from the filter at high temperatures caused increase of noise from the photo detectors and, respectively, limited opportunities for the determination of less volatile elements.…”
Section: Optimal Physical Parameters Of the Atomizermentioning
confidence: 99%
“…Filter atomization in conventional AAS based on line sources was used as alternative to the traditional platform tube technique for the direct determination of high and medium volatile elements in samples associated with strong spectral and chemical interferences [11][12][13][14][15][16][17][18][19][20][21][22][23][24]. It provided reduction of interferences without involvement of chemical modifiers and the possibility for using larger sampling volumes of organic or inorganic liquids, while keeping the temperature program short.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Cette mise au point est poussée dans son extrême avec Mbileni et al (2002) où un four transverse poreux est utilisé pour injecter l'échantillon. La modification de la partie four de cet appareil n'est pas proposée dans le commerce mais semble pouvoir accepter des volumes d'injection plus important.…”
Section: éTat De L'art Des Applications Actuelles Pour Les Produits Punclassified