1951
DOI: 10.1109/t-aiee.1951.5060554
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Instantaneous Currents and Voltages by Means of Alpha, Beta, and Zero Components

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
94
0
9

Year Published

2014
2014
2021
2021

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 234 publications
(111 citation statements)
references
References 2 publications
0
94
0
9
Order By: Relevance
“…The possible space vectors can be found by taking the Clarke transform of the line-to-neutral voltage of a six-step 3-phase bridge [19]. The voltage setpoint in the dq frame can be referred to the stationary reference frame through the inverse Park transform, rendering a complex space vector voltage setpoint, V * [20].…”
Section: B Space Vector Pulse-width Modulationmentioning
confidence: 99%
“…The possible space vectors can be found by taking the Clarke transform of the line-to-neutral voltage of a six-step 3-phase bridge [19]. The voltage setpoint in the dq frame can be referred to the stationary reference frame through the inverse Park transform, rendering a complex space vector voltage setpoint, V * [20].…”
Section: B Space Vector Pulse-width Modulationmentioning
confidence: 99%
“…abc to α, β, 0 Using Clarke power invariant transformation [26] (1) αβ0 values in time domain for the phase voltages and currents are obtained. In the case the neutral current is measured, zerosequence current is directly obtained from the sensor reading.…”
Section: Digital Signal Processing Implementationmentioning
confidence: 99%
“…n-phase inverter produces m=2 (4) In order to avoid calculation in case of large number of vectors used in drive, the n-phase modulator is proposed Its operation will involve converting a vector quantities from the n-phase coordinates to orthogonal coordinates and vice versa. In the literature [2,8] drive systems with multi-hysteresis current regulator are described (Fig. 2) Usually, the control system applies the speed control loop The speed controller generates a reference value component i qref of the current vector.…”
Section: Fig 1 Division Of Basic Vector Control Strategies Used In mentioning
confidence: 99%
“…Control strategies like: rotor-oriented control (ROC) or field-oriented control (FOC) have been realized, basing on coordinate transformations. For 3-phase systems, the space vector written for stationary systems phase X ABC is transformed into orthogonal X αβ through the Clarke transformation [8]. As the paper addresses n-phase systems built from a number of phases n > 3, one should define the transformation of the n-phase to orthogonal transformation, which is a general-M. Janaszek…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation