2014
DOI: 10.1016/j.chemosphere.2013.12.085
|View full text |Cite
|
Sign up to set email alerts
|

Determination of free Bisphenol A (BPA) concentrations in breast milk of U.S. women using a sensitive LC/MS/MS method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

6
56
1
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 155 publications
(65 citation statements)
references
References 37 publications
6
56
1
1
Order By: Relevance
“…Despite the great improvement in ESI+ ionization of the resulting BPA derivative, the MS/MS fragmentation of the resulting ion yields only reagent‐specific product ions, which drastically reduces the specificity of the method. Chemical derivatization using pyridine‐3‐sulfonyl (PS) chloride has been very recently applied for the determination of BPA in different kinds of biological matrices with successful results with regard to both sensitivity and specificity 23, 24, 25, 26. This derivatization reagent has been reported to present a major advantage over the widely used dansyl chloride, since MS/MS transitions involve analyte‐specific product ions rather than reagent‐specific product ions 23, 24, 27.…”
mentioning
confidence: 99%
“…Despite the great improvement in ESI+ ionization of the resulting BPA derivative, the MS/MS fragmentation of the resulting ion yields only reagent‐specific product ions, which drastically reduces the specificity of the method. Chemical derivatization using pyridine‐3‐sulfonyl (PS) chloride has been very recently applied for the determination of BPA in different kinds of biological matrices with successful results with regard to both sensitivity and specificity 23, 24, 25, 26. This derivatization reagent has been reported to present a major advantage over the widely used dansyl chloride, since MS/MS transitions involve analyte‐specific product ions rather than reagent‐specific product ions 23, 24, 27.…”
mentioning
confidence: 99%
“…Inoue et al (2004) showed PFOS blood concentrations in pregnant humans of 4.9-17.6ng/ml and 1.6-5.3ng/ml in the developing foetus, indicating the placental barrier is not entirely effective at removing certain amphipathic PFCs. Zimmers et al (2014) have also been detected in human breast milk (Lankova et al 2013). Here, eight perfluoroalkyl compounds were detected in the breast milk of 50 humans including PFOA (0.012-0.128ng/ml), PFOS (0.007-0.114pg/ml) and PFNA (<0.006-0.015ng/ml) as well as TBBPA at levels of <0.060-16.2ng/ml (Lankova et al 2013).…”
Section: Occurrence and Possible Effects Of Pcps/ecs In Humansmentioning
confidence: 87%
“…As listed from Table S1, methods like HPLC [19,38], GC-MS [21], LC/MS [20] and LC-MS/MS [39] can detect BPA with high sensitivity and selectivity, but they require complicated instruments and highly trained operators. The electrochemistry methods [40,41] show low detection limit and broad linear range, but possibly involve the disadvantages of instability and interference of organics in anodic/catholic stripping voltammetry.…”
Section: Methods Performance Comparisonmentioning
confidence: 99%
“…For that reason, the identification and determination of trace amounts of BPA is very necessary. The most frequently used methods include high performance liquid chromatography (HPLC) [19], high performance liquid chromatography-mass spectrometry (MS) [20], and gas chromatography-mass spectrometry (GC-MS) [21]. However, these methods are still involved in some problems such as complex instruments, high cost, time-consuming, and particularly low selectivity.…”
Section: Introductionmentioning
confidence: 99%