2005
DOI: 10.1016/j.chroma.2005.02.057
|View full text |Cite
|
Sign up to set email alerts
|

Determination of (fluoro)quinolone antibiotic residues in pig kidney using liquid chromatography–tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
27
0

Year Published

2006
2006
2014
2014

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 85 publications
(28 citation statements)
references
References 24 publications
0
27
0
Order By: Relevance
“…However, these methods are complicated, timeconsuming, and specificity-lacking (Kurittu et al, 2000). Instrumental methods, including liquid chromatography-mass spectrometry (LC-MS) and highperformance liquid chromatography (HPLC) (Johnston et al, 2002;van Vyncht et al, 2002;EspinosaMansilla et al, 2005;Toussaint et al, 2005a;2005b;Zeng et al, 2005), are the most current widely used methods for CPFX residues detection. These methods are sensitive and highly specific, but they require expensive equipment, large volumes of solvents, and highly trained individuals for operating complicated instruments, with time-consuming sample cleanup processes.…”
Section: Introductionmentioning
confidence: 99%
“…However, these methods are complicated, timeconsuming, and specificity-lacking (Kurittu et al, 2000). Instrumental methods, including liquid chromatography-mass spectrometry (LC-MS) and highperformance liquid chromatography (HPLC) (Johnston et al, 2002;van Vyncht et al, 2002;EspinosaMansilla et al, 2005;Toussaint et al, 2005a;2005b;Zeng et al, 2005), are the most current widely used methods for CPFX residues detection. These methods are sensitive and highly specific, but they require expensive equipment, large volumes of solvents, and highly trained individuals for operating complicated instruments, with time-consuming sample cleanup processes.…”
Section: Introductionmentioning
confidence: 99%
“…The mobile phase consisted of a mixture of 0.1% formic acid in acetonitrile and 0.1% formic acid in water. Several gradient programs were tested to ensure optimum quinolones separation on each of the studied chromatographic columns taking into account that two of the studied quinolones have the same molecular mass and may interfere in the case of co-elution [37,38]. The results showed that all of the studied quinolones can be separated using the same gradient program on the two studied core-shell particles based columns: Kinetex PFP and Poroshell 120 EC-C18 (Table I).…”
Section: High-performance Liquid Chromatography-tandem Mass Spectromementioning
confidence: 99%
“…Although the separation time on Gemini column was higher than other studied columns, it is short enough to ensure good separation at low reagent and analysis time consumption. The MS/MS detection parameters were also optimized starting with the parameters described in [37,39]. In our work, two product ions for each determined compound have been selected (from their corresponding precursor ions), which complies with the requirements proposed in current EU legislation for a minimum total score of 3 identification points for confirmatory MS method [35].…”
Section: High-performance Liquid Chromatography-tandem Mass Spectromementioning
confidence: 99%
“…Toussaint et al developed a method for isolating 11 quinolones from pig kidney [306]. Other groups have developed methods for isolating quinolone residues from animal tissues [307]. More novel methods have also been developed including hot water extraction [87].…”
Section: Quinolonesmentioning
confidence: 99%