2012
DOI: 10.1016/j.sab.2012.04.003
|View full text |Cite
|
Sign up to set email alerts
|

Determination of chlorine in food samples via the AlCl molecule using high-resolution continuum source molecular absorption spectrometry in a graphite furnace

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
40
0
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(41 citation statements)
references
References 11 publications
0
40
0
1
Order By: Relevance
“…Pereira et al 27,28 carried out the determination of chlorine using SrCl molecule and obtained LOD values of 2.0 µg g -1 , in a method for biological samples, and 5.6 µg g -1 in a method for coal. The determination of chlorine via CaCl molecule in food samples, employing two sample treatments, was also accomplished by Fechetia et al, 20 obtaining LOD values of 9.0 and 18 µg g -1 . Under the optimized conditions, the characteristic mass of the method was 0.10 ng.…”
Section: Matrix Interferencementioning
confidence: 99%
See 1 more Smart Citation
“…Pereira et al 27,28 carried out the determination of chlorine using SrCl molecule and obtained LOD values of 2.0 µg g -1 , in a method for biological samples, and 5.6 µg g -1 in a method for coal. The determination of chlorine via CaCl molecule in food samples, employing two sample treatments, was also accomplished by Fechetia et al, 20 obtaining LOD values of 9.0 and 18 µg g -1 . Under the optimized conditions, the characteristic mass of the method was 0.10 ng.…”
Section: Matrix Interferencementioning
confidence: 99%
“…16,17 Chlorine determination by high-resolution continuum source molecular absorption spectrometry (HR-CS MAS) has been accomplished by detection of several diatomic molecules. 16,18 The most widely reported in the literature is AlCl [19][20][21][22][23][24][25] due to its high energy bond and well separated band heads, making it effective the background correction. 17,26 Strontium monochloride (SrCl) was applied for chlorine determination in different types of samples (coal, milk, animal organs and tissues, and wheat flour).…”
Section: Introductionmentioning
confidence: 99%
“…Alternatively, the sampling cup was pre-treated with a total of 200 μg Pd as permanent modifier (10 injections of 20 μL of the stock solution). Calcium and Nd were then prereduced using a Tp of 1000°C [18], before the addition of each sample. Chlorine quantification in CRM was carried out using calibration against aqueous or solid standards using Pd + Nd or Pd + Ca pre-dried as modifiers and also without modifier using a solid standard.…”
Section: Analytical Proceduresmentioning
confidence: 99%
“…In addition, losses of halogens bound to organic structures have been reported in the literature for some biological samples, making this technique difficult to apply widely without additional pretreatment [37,40,47,82].…”
Section: Determination Of Halogens In Biological Samplesmentioning
confidence: 99%