2013
DOI: 10.1007/s00216-013-7077-9
|View full text |Cite
|
Sign up to set email alerts
|

Analytical methods for the determination of halogens in bioanalytical sciences: a review

Abstract: Fluorine, chlorine, bromine, and iodine have been studied in biological samples and other related matrices owing to the need to understand the biochemical effects in living organisms. In this review, the works published in last 20 years are covered, and the main topics related to sample preparation methods and analytical techniques commonly used for fluorine, chlorine, bromine, and iodine determination in biological samples, food, drugs, and plants used as food or with medical applications are discussed. The c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
89
0
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 144 publications
(97 citation statements)
references
References 200 publications
(312 reference statements)
0
89
0
1
Order By: Relevance
“…were analyzed by the Dionex ICS-1100 ion chromatography system (Dionex Corp., Sunnyvale, CA, USA). The Cl -anion was determined according to the spectrophotometric method (gelatin-alcohol water solution as protective colloid) (Mello et al 2013).…”
Section: Determination Of Leaf Inorganic Ions Contentmentioning
confidence: 99%
“…were analyzed by the Dionex ICS-1100 ion chromatography system (Dionex Corp., Sunnyvale, CA, USA). The Cl -anion was determined according to the spectrophotometric method (gelatin-alcohol water solution as protective colloid) (Mello et al 2013).…”
Section: Determination Of Leaf Inorganic Ions Contentmentioning
confidence: 99%
“…The determination of halogens has been performed by inductively coupled plasma mass spectrometry (ICP-MS), inductively coupled plasma atomic emission spectrometry (ICP OES), and ion chromatography (IC) [15,16]. In particular, ICP-MS presents high selectivity and suitable LODs for Br and I determination in low concentrations [16].…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, the high acidity of digests could cause interferences on the determination by ICP-MS and a dilution or neutralization of digests is often required (Todoli & Mermet, 1999). In this way, alkaline media (e.g., KOH, TMAH, CFA-C) could be used to minimize losses, but in general these procedures provide only a dissolution of the sample and so interferences of the organic matrix that remains in digests are expected in ICP-MS determination (Mello et al, 2013;Sullivan & Zywicki, 2012).…”
Section: Introductionmentioning
confidence: 98%
“…The lack of information about the content of Br and I in whey proteins could be explained at least partially by the analytical challenges related to their determination at low concentration (Mello et al, 2013). In this way, several techniques such as ion chromatography, potentiometry with ion-selective electrodes, inductively coupled plasma optical emission spectrometry, and graphite furnace molecular absorption spectrometry present limitations due to the unsuitable limit of detection (LOD) for the determination of Br and I in whey proteins.…”
Section: Introductionmentioning
confidence: 98%