2004
DOI: 10.1016/j.chroma.2004.01.013
|View full text |Cite
|
Sign up to set email alerts
|

Determination of biogenic amines in fish tissues by ion-exchange chromatography with conductivity detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
40
2
2

Year Published

2007
2007
2016
2016

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 107 publications
(47 citation statements)
references
References 7 publications
1
40
2
2
Order By: Relevance
“…The LODs and LOQs for BAs were found to be in the range of 3.8-31.3 and 12.7-104 ng L −1 , respectively (Table 1). These values were comparatively lower than those obtained in previously reported procedures [30][31][32].…”
Section: Methods Validationcontrasting
confidence: 80%
“…The LODs and LOQs for BAs were found to be in the range of 3.8-31.3 and 12.7-104 ng L −1 , respectively (Table 1). These values were comparatively lower than those obtained in previously reported procedures [30][31][32].…”
Section: Methods Validationcontrasting
confidence: 80%
“…Under such defined chromatographic and conductometric conditions, the analytical performance expressed in terms of LOD, linear range, sensitivity and coefficients of correlation are summarized in Table 2. As can be seen, the LODs obtained here and determined at a S/N equal to 3, comprise between 20 and 65 nM and can be considered similar or slightly lower than those obtained with other analytical procedures based on LC or capillary ion electrophoresis coupled with spectrophotometric, MS and electrochemical detection [11,18]. In addition, Table 2 shows an overview of the conductometric capability towards the detection of several aliphatic mono-and polyamines expressed in terms of molar sensitivity (nS/ lM).…”
Section: Chromatographic Characterizationsupporting
confidence: 74%
“…The limit of quantification (LOQ) determined at a S/N of 10 evaluated with the proposed SPE procedure, using a preconcentration factor of 5:1 (i. e. 10 mL of standard solution extracted with (1 + 1) mL of BaCl 2 and H 2 SO 4 solutions), ranged between 10 and 20 nM for all investigated molecules. The LOD and the LOQ obtained here can be considered sensibly lower than those obtained with other analytical procedures based on LC technique with suppressed conductivity detection [11,18].…”
Section: Spe Of Aminescontrasting
confidence: 51%
“…It is also possible to use acids: hydrochloric (Gennaro et al, 2003;Cinquina et al, 2004;Martuscelli et al, 2005); perchloric (Novella-Rodrı´guez et al, 2000;Pinho et al, 2001;Minocha and Long, 2004); trichloroacetic (Joosten and Olieman, 1986;Pattono et al, 2000;Lapa-Guimara˜es and Pickova, 2004); or sulfosalicylic (Buts et al, 1995). Acids can extract amines that are bound to components of the matrix.…”
Section: Introductionmentioning
confidence: 97%