“…Previously, it was found that, the rate of derivatization increases with increasing concentration of nitrite ions, and is almost completed within 3 min, with 6 mmol L −1 NaNO 3 , 0.5 mol L −1 H 2 SO 4 , at temperature of 20 ± 5°C, of optimal conditions [23]. Therefore, these conditions were selected as the default for further optimization.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Previously, it was found that, the rate of derivatization increases with increasing concentration of nitrite ions, and is almost completed within 3 min, with 6 mmol L −1 NaNO 3 , 0.5 mol L −1 H 2 SO 4 , at temperature of 20 ± 5°C, of optimal conditions [23]. Therefore, these conditions were selected as the default for further optimization.…”
Section: Resultsmentioning
confidence: 99%
“…The data show the proposed method is superior with respect to all key analytical figures of merit. The described method is fully automated and more sensitive [23], since the application of dispersive solvent that can affect the solubility of the analyte in the aqueous phase is avoided.…”
Section: Analytical Performancementioning
confidence: 99%
See 1 more Smart Citation
“…The studied membrane has higher free volume, which significantly effects the transport of low molecular substances through it. The stepwise injection analysis [20][21][22] was chosen for the automation of methanol and ethanol determination in biodiesel because its manifold allows to mix solutions by a gas flow. This feature can be used to increase the efficiency of methanol and ethanol penetration during vapor permeation.…”
Section: Introductionmentioning
confidence: 99%
“…The SWIA [21][22][23][24][25] was chosen for the automation of curcumin determination because it provides high efficiency of mixing sample and reagent solutions. The SWIA manifold is similar to the zone fluidics [26], sequential injection-lab at valve [27] and flow batch [28] manifolds.…”
Section: Introductionmentioning
confidence: 99%