2008
DOI: 10.1016/j.nima.2008.02.095
|View full text |Cite
|
Sign up to set email alerts
|

Determination of a small vertical electron beam profile and emittance at the Swiss Light Source

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
32
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 42 publications
(33 citation statements)
references
References 13 publications
1
32
0
Order By: Relevance
“…We note that the PSF of the camera can be decomposed further as the x-ray camera has an x-ray screen, a lens, and a CCD chip; however, we consider this system as a whole with its own PSF. Equating S to zero in expression (1) gives the point spread function width of the system, AE 0 . Let us focus on the PSF width of the diffraction through the pinhole.…”
Section: Point Spread Function Of the X-ray Pinhole Camera: Analymentioning
confidence: 99%
See 2 more Smart Citations
“…We note that the PSF of the camera can be decomposed further as the x-ray camera has an x-ray screen, a lens, and a CCD chip; however, we consider this system as a whole with its own PSF. Equating S to zero in expression (1) gives the point spread function width of the system, AE 0 . Let us focus on the PSF width of the diffraction through the pinhole.…”
Section: Point Spread Function Of the X-ray Pinhole Camera: Analymentioning
confidence: 99%
“…Third generation synchrotron light sources are characterized by low emittance, and with the top-up operation becoming routine, they can afford (in terms of reduced lifetime) to operate at extremely low emittance coupling [1]. The measurement of the emittance can be done indirectly by measuring the transverse beam size using the synchrotron radiation produced by it.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Each ring in the MAX IV project will be equipped with two diagnostic beamlines based on imaging of the electron beam using visible to ultraviolet synchrotron radiation. The design will be similar to that given by Andersson et al (2008) and Saá Herná ndez et al…”
Section: Rf Systemmentioning
confidence: 99%
“…This has been demonstrated by a first monitor built in 2008 at SLS for the determination of the vertical beam emittance [1]. The monitor uses the so-called π-polarization method to determine the vertical beam size from vertically polarized (π-polarized) vis-UV SR imaged onto a CCD camera.…”
Section: Introductionmentioning
confidence: 99%