2011
DOI: 10.1016/j.aca.2011.03.017
|View full text |Cite
|
Sign up to set email alerts
|

Determination of 40 currently used pesticides in airborne particulate matter (PM 10) by microwave-assisted extraction and gas chromatography coupled to triple quadrupole mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
28
0
2

Year Published

2013
2013
2023
2023

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 60 publications
(34 citation statements)
references
References 24 publications
1
28
0
2
Order By: Relevance
“…Although the EI mode was used for the general method, a supplementary methodology based on GC-(NCI) MS using the selected ion recording (SIR) mode was proposed for quantification and confirmation of OC pesticides as it allowed notable sensitivity improvement for these compounds. As regards confirmation identity, it is based on the presence of at least two SRM transitions 25,71,72,76,77,79 and R t agreement, although several authors also took into account the experimental relative intensity ratio of the sample and the theoretical ratio of the reference standard, using the maximum deviations established in the European The GC-MS/MS methods applied in the analysis of environmental samples presented excellent sensitivity. In the case of soils and sediments, the lowest level validated was as low as 1 ng g −176 or 5 ng g −1 .…”
Section: Gc-ms/ms Applications In the Analysis Of Environmental Samplesmentioning
confidence: 99%
See 2 more Smart Citations
“…Although the EI mode was used for the general method, a supplementary methodology based on GC-(NCI) MS using the selected ion recording (SIR) mode was proposed for quantification and confirmation of OC pesticides as it allowed notable sensitivity improvement for these compounds. As regards confirmation identity, it is based on the presence of at least two SRM transitions 25,71,72,76,77,79 and R t agreement, although several authors also took into account the experimental relative intensity ratio of the sample and the theoretical ratio of the reference standard, using the maximum deviations established in the European The GC-MS/MS methods applied in the analysis of environmental samples presented excellent sensitivity. In the case of soils and sediments, the lowest level validated was as low as 1 ng g −176 or 5 ng g −1 .…”
Section: Gc-ms/ms Applications In the Analysis Of Environmental Samplesmentioning
confidence: 99%
“…25,69 The purity of the air was evaluated by analyzing the airborne particulate matter performing the validation at the lowest level of 10 ng mL −1 . 71 As regards water samples, the lowest level validated is reported to be 0.14 ng L −1 for a variety of priority organic pollutants. 73 As expected, the lowest level validated in waste water was much higher, as a consequence of the higher matrix complexity.…”
Section: Gc-ms/ms Applications In the Analysis Of Environmental Samplesmentioning
confidence: 99%
See 1 more Smart Citation
“…Chromatographic techniques are the most commonly used tools to determine pesticide residues. [7][8][9][10][11] In recent years pre-concentration methods and sample cleanup steps such as quick, easy, cheap, effective, rugged and safe (QuEChERS), 12 microwave assisted extraction, 13 extraction with an ionic liquid, 14 solid phase extraction, 15 solid phase microextraction 16 and matrix solid phase dispersion 17 were employed with good results. No electroanalytical procedure was found in literature for the fipronil determination.…”
Section: Introductionmentioning
confidence: 99%
“…30 O emprego da cromatografia gasosa acoplada à espectrometria de massas em série (GC-MS/MS, do inglês gas chromatography with tandem mass spectrometry) possibilita um grande aumento de seletividade e da detectabilidade. 31 Na varredura de monitoramento do íon selecionado (SRM do inglês, selected reaction monitoring) monitora-se a fragmentação de um íon precursor selecionado no Q1 e seus correspondentes íons produtos que são filtrados em Q3. A ausência da varredura permite que o equipamento focalize apenas o precursor e o produto, aumentando a sensibilidade para o monitoramento, que é associado a um aumento na seletividade.…”
unclassified