2001
DOI: 10.1016/s0039-128x(01)00109-x
|View full text |Cite
|
Sign up to set email alerts
|

Determination of 17α-hydroxypregnenolone in human plasma by routine isotope dilution mass spectrometry using benchtop gas chromatography-mass selective detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2002
2002
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 12 publications
0
4
0
Order By: Relevance
“…Pentafluorophenyldimethylsilyl-TMS ether (flophemesyl) derivatives give intense molecular ions in MS that are attractive for GC-MS analysis (Choi and Chung, 1999;Choi et al 2001). Heptafluorobutyrates have been used for quantitative analysis of several steroids (Scherer et al, 1998;Wudy et al, 2000Wudy et al, , 2001Wudy et al, , 2002. Bismethylenedioxypentafluoropropionate derivatives have been used in the analysis of cortisol metabolites (Furuta et al, 2000a, b).…”
Section: Derivative Formationmentioning
confidence: 99%
“…Pentafluorophenyldimethylsilyl-TMS ether (flophemesyl) derivatives give intense molecular ions in MS that are attractive for GC-MS analysis (Choi and Chung, 1999;Choi et al 2001). Heptafluorobutyrates have been used for quantitative analysis of several steroids (Scherer et al, 1998;Wudy et al, 2000Wudy et al, , 2001Wudy et al, , 2002. Bismethylenedioxypentafluoropropionate derivatives have been used in the analysis of cortisol metabolites (Furuta et al, 2000a, b).…”
Section: Derivative Formationmentioning
confidence: 99%
“…In addition, 4-androstenedione, cortisol, DHEA, 11-deoxycortisol, 17-hydroxypregnenolone (17OHPreg), and 17-hydroxyprogesterone (17OHP) were determined by isotope dilution gas chromatography–mass spectrometry (GC–MS) as described elsewhere (Wudy et al, 2001; Wudy and Hartmann, 2004). Briefly, cell supernatant was equilibrated with internal standard (deuterium-labeled analogs of analytes).…”
Section: Methodsmentioning
confidence: 99%
“…This was a difficult detector to keep for routine use and will not be considered here. GC-MS has been found also to be a very reliable quantitative method for steroids in plasma such as DHAS, 17-OHP, AS, testosterone, 17-hydroxpregnenolone, 11-deoxycortisol and DHAS (7, 8, 9, 10, 11, 12, 13). It is superior to other methods, because of the improved specificity of assays through separation of steroids in the sample extract, which is needed particularly for tests on newborn infants.…”
Section: Gas Chromatographymentioning
confidence: 99%
“…For steroids, those reference methods have relied upon stable-isotope dilution analyses with GC coupled with mass spectrometry (MS) (6, 7, 8). The dual selectivity of the separation of a mixture of components and specific ion detection enables exceptionally high accuracy without interferences (9, 10, 11, 12, 13). Some immunoassays have approached that level of accuracy, but only when the method includes extraction and chromatographic purification, again limited to very specialised laboratories (14, 15).…”
Section: Introductionmentioning
confidence: 99%