1975
DOI: 10.1016/0017-9310(75)90139-8
|View full text |Cite
|
Sign up to set email alerts
|

Determination des proprietes thermophysiques de liquides non-Newtoniens a l'aide d'une cellule a cylindres coaxiaux

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
33
0
5

Year Published

1982
1982
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 54 publications
(38 citation statements)
references
References 3 publications
0
33
0
5
Order By: Relevance
“…Thermal conductivity at various temperatures and water contents were measured using the method described by BELLET et al 4 , based on a cylindrical cell, where the liquid whose properties are determined fills the annular space between two concentric cylinders. The physical characteristic is specified in Figure 1, which presents: two coaxial copper cylinders (a and b), 180 mm in length, separated by a 2 mm annular space, which was filled with the sample; 50 mm thick covers (c) made of a low thermal conductivity material (0.225 W.m -1°C ) to prevent axial heat transfer; a heater made with a constantan wire (resistance 15 W), electrically insulated by a varnish and coiled around a copper stick; two thermocouples type T to measure the temperature differences between the two cylinders, located at half the length of the cell, with wires placed inside 0.5 mm gaps, parallel to the cell axis.…”
Section: Thermal Conductivitymentioning
confidence: 99%
See 1 more Smart Citation
“…Thermal conductivity at various temperatures and water contents were measured using the method described by BELLET et al 4 , based on a cylindrical cell, where the liquid whose properties are determined fills the annular space between two concentric cylinders. The physical characteristic is specified in Figure 1, which presents: two coaxial copper cylinders (a and b), 180 mm in length, separated by a 2 mm annular space, which was filled with the sample; 50 mm thick covers (c) made of a low thermal conductivity material (0.225 W.m -1°C ) to prevent axial heat transfer; a heater made with a constantan wire (resistance 15 W), electrically insulated by a varnish and coiled around a copper stick; two thermocouples type T to measure the temperature differences between the two cylinders, located at half the length of the cell, with wires placed inside 0.5 mm gaps, parallel to the cell axis.…”
Section: Thermal Conductivitymentioning
confidence: 99%
“…The cell was calibrated with distilled water. Details of this method, cell calibration and experimental tests can be found elsewhere 4,19,25 .…”
Section: Thermal Conductivitymentioning
confidence: 99%
“…Thermal conductivity was measured according to the method described by Bellet, Sengelin and Thirriot (1975). This technique uses a cylindrical cell, composed of two coaxial cylinders with an annular space, which is filled with the liquid whose properties are to be determined.…”
Section: Determination Of Thermophysical Propertiesmentioning
confidence: 99%
“…Equation (1), as described by Bellet et al (1975), can be used to calculate the sample thermal conductivity, λ from the experimental measurements of T 1 and T 2 under steady state conditions. ).…”
Section: Determination Of the Freezing Point Depressionmentioning
confidence: 99%