2010
DOI: 10.1590/s0100-40422010000700020
|View full text |Cite
|
Sign up to set email alerts
|

Determinação seletiva de tributilestanho na presença de Sn(IV) em amostras ambientais usando HG-ICP OES e Saccharomyces cerevisiae como material sorvente

Abstract: Recebido em 9/11/09; aceito em 15/3/10; publicado na web em 20/7/10 SELECTIVE DETERMINATION OF TRIBUTYLTIN IN THE PRESENCE OF Sn(IV) IN ENVIRONMENTAL SAMPLES USING HG-ICP OES AND Saccharomyces cerevisiae AS SORBING MATERIAL. A method for selective determination of tributyltin in the presence of Sn(IV) by combining hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP OES) and solid phase extraction (SPE) using baker's yeast is proposed. The procedure is based on selective retentio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 30 publications
0
7
0
Order By: Relevance
“…A rapid method (7 minute GC separation) for the determination of OTCs combined SPME with GC-ICP-MS. 135 A baker's yeast has been proposed as a suitable solid phase extractant. 136 Multi-element methods are always welcome as the effort required to carry out speciation analysis is still considerable. A method for the determination of Br and I species in drinking water by IC-ICP-MS 137 used an ICS-A23 column to separate the species present with a mobile phase of 0.03 M ammonium carbonate.…”
Section: Speciationmentioning
confidence: 99%
“…A rapid method (7 minute GC separation) for the determination of OTCs combined SPME with GC-ICP-MS. 135 A baker's yeast has been proposed as a suitable solid phase extractant. 136 Multi-element methods are always welcome as the effort required to carry out speciation analysis is still considerable. A method for the determination of Br and I species in drinking water by IC-ICP-MS 137 used an ICS-A23 column to separate the species present with a mobile phase of 0.03 M ammonium carbonate.…”
Section: Speciationmentioning
confidence: 99%
“…262 The procedure is based on selective retention of TBT by the yeast at pH 6. A detection limit of 1.9 mg L À1 and a quantification limit of 6.3 mg L À1 were obtained.…”
Section: Tinmentioning
confidence: 99%
“…The accuracy of the method was validated against fortified water TMDA 61 (NWRI) and Dogfish Liver DOLT-3 (NRCC) CRMs. Silva et al 36 employed HG-ICP-OES and SPE (with a baker's yeast solid phase) for the selective determination of tributyltin in the presence of Sn IV in river water, seawater, and biological abstracts. Unal and Yalcin 163 developed a continuous-flow HG laserinduced breakdown spectroscopy system for the determination of Sn in aqueous samples.…”
Section: Cadmium Feng and Liumentioning
confidence: 99%
“…Silva and Brazilian co-workers 36 selectively determined tributyltin in the presence of Sn IV in environmental samples using HG-ICP-OES and saccharomyces cerevisiae (Baker's yeast) as sorbing material. The procedure was based on the retention of TBT by the yeast at pH 6.…”
mentioning