Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2009
DOI: 10.1016/j.still.2009.05.001
|View full text |Cite
|
Sign up to set email alerts
|

Detection of soil water in macropores of undisturbed soil using microfocus X-ray tube computerized tomography (μCT)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
45
0
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
6
1
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 71 publications
(50 citation statements)
references
References 28 publications
2
45
0
1
Order By: Relevance
“…As was also found by Tippkötter et al [47] and generally unlike in the case of images obtained with table-top, polychromatic X-ray computed tomography scanners [5,23,24,25], the histograms of the 3D SR-µCT images of the soil samples display three distinct peaks (Fig. 1).…”
Section: Sr-µct Scanssupporting
confidence: 69%
See 1 more Smart Citation
“…As was also found by Tippkötter et al [47] and generally unlike in the case of images obtained with table-top, polychromatic X-ray computed tomography scanners [5,23,24,25], the histograms of the 3D SR-µCT images of the soil samples display three distinct peaks (Fig. 1).…”
Section: Sr-µct Scanssupporting
confidence: 69%
“…They are able under these conditions to clearly observe pendular rings of water between two clayloam soil aggregates at a resolution close to 6 µm. Tippkötter et al [47] adopt a similar focus, in undisturbed soil samples, and are able with a table-top X-ray CT scanner to visualize the presence of water films coating the inner surfaces of meso-and macropores. These data obtained by Carminati et al [11] and Tippkötter et al [47], or equivalent CT data obtained in other soils, could in principle be used to assess whether existing pore-scale models of water distribution in soils are adequate.…”
Section: Introductionmentioning
confidence: 99%
“…Others have reported resolution down to 1 µm when using an X-ray scanner optimized for smaller sample sizes (e.g. Tippkötter et al, 2009). By using a monochromatic X-ray source Voltolini et al (2017) imaged soil micro-aggregates with a sub-micron resolution.…”
Section: Discussionmentioning
confidence: 99%
“…A tomografia computadorizada também permite a obtenção de imagens em um tempo relativamente curto, mesmo em sistemas de primeira geração (horas), quando comparada com a micromorfologia (semanas ou meses). Sistemas de segunda geração são capazes de gerar imagens em 3D, com resoluções micrométricas e aquisição da imagem em minutos, sendo ferramentas interessantes para uma melhor caracterização do solo (Tippkotter et al, 2009).…”
Section: Resultsunclassified