2002
DOI: 10.1016/s1076-6332(03)80203-9
|View full text |Cite
|
Sign up to set email alerts
|

Detection of Individual Microbubbles of an Ultrasound Contrast Agent

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
28
0

Year Published

2003
2003
2017
2017

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 53 publications
(28 citation statements)
references
References 4 publications
0
28
0
Order By: Relevance
“…The backscatter by a bubble is proportional to the sixth power of its diameter; the effectiveness of echo response is also dependent on the ultrasound frequency. 17 It was recently shown that smaller bubbles indeed do not present themselves as efficient scatterers of ultrasound and cannot be detected at all unless the imaging is performed at high MI, 11 and we intentionally avoided high MI in this study to minimize reduction of microbubble concentration during imaging. A second probable explanation could reside with issue of the interrogated volume calculation.…”
Section: Klibanov Et Almentioning
confidence: 99%
See 1 more Smart Citation
“…The backscatter by a bubble is proportional to the sixth power of its diameter; the effectiveness of echo response is also dependent on the ultrasound frequency. 17 It was recently shown that smaller bubbles indeed do not present themselves as efficient scatterers of ultrasound and cannot be detected at all unless the imaging is performed at high MI, 11 and we intentionally avoided high MI in this study to minimize reduction of microbubble concentration during imaging. A second probable explanation could reside with issue of the interrogated volume calculation.…”
Section: Klibanov Et Almentioning
confidence: 99%
“…Recently, it was reported that very dilute dispersions of microbubbles 11,12 do present individual foci of ultrasound scatterers that might be consistent with the individual microbubbles responsible; however, direct microbubble counting comparison has not been reported. Such independent counting of microbubbles could be performed by Coulter counting.…”
mentioning
confidence: 99%
“…Data were recorded on a 1.25-cm videotape using an S-VHS recorder. Phospholipid-coated perfluorocarbon gas microbubbles were manufactured at the University of Virginia as reported previously (24). Microbubble concentration and size distribution were determined by electrozone sensing with a Coulter Multisizer IIe (Beckman-Coulter).…”
mentioning
confidence: 99%
“…They have a typical size of 2–6 μm, and can circulate in the blood and pass through CNS capillaries. Since microbubbles contain a gas–liquid interface that is highly responsive to ultrasound mechanical stress, microbubbles provide strong ultrasound energy scattering that enables microbubbles to be applied in diagnostic ultrasound as a contrast agent [2123]. In addition, ultrasound energy interactions with microbubbles have been confirmed to transiently permeate CNS capillaries [2426].…”
Section: Introductionmentioning
confidence: 99%