2021
DOI: 10.3390/s21051658
|View full text |Cite
|
Sign up to set email alerts
|

Detection of Gadolinium with an Impedimetric Platform Based on Gold Electrodes Functionalized by 2-Methylpyridine-Substituted Cyclam

Abstract: Gadolinium is extensively used in pharmaceuticals and is very toxic, so its sensitive detection is mandatory. This work presents the elaboration of a gadolinium chemical sensor based on 2-methylpyridine-substituted cyclam thin films, deposited on gold electrodes, using electrochemical impedance spectroscopy (EIS). The 2-methylpyridine-substituted cyclam (bis-N-MPyC) was synthesized in three steps, including the protection of cyclam by the formation of its CH2-bridged aminal derivative; the product was characte… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 47 publications
0
7
0
Order By: Relevance
“…5., a significant decrease in the contact angle of water drops from 83±3° for the PSF membrane surface to 9±2.5° for the surface of 2 wt % Gd 2 O 3 embedded PSF membrane. This decrease of contact angle revealed Gd's hydrophilic property, which is clarified by the presence of the polar -OH groups on the Gadolinium(III) hydroxide hydrate surface [15].…”
Section: Membrane Hydrophilicitymentioning
confidence: 95%
“…5., a significant decrease in the contact angle of water drops from 83±3° for the PSF membrane surface to 9±2.5° for the surface of 2 wt % Gd 2 O 3 embedded PSF membrane. This decrease of contact angle revealed Gd's hydrophilic property, which is clarified by the presence of the polar -OH groups on the Gadolinium(III) hydroxide hydrate surface [15].…”
Section: Membrane Hydrophilicitymentioning
confidence: 95%
“…Nyquist diagrams were recorded with increasing metal concentrations ranging from 10 −10 M up to 10 −4 M. All our measurements were performed in triplicates ( n = 3) at a negative bias of −0.3 V. This value allows an improved definition in the Nyquist plot, being sufficiently low to reduce any corrosion phenomenon [ 4 ].…”
Section: Methodsmentioning
confidence: 99%
“…Many techniques are used for heavy metal quantification but are often complex and expensive, with other intrinsic issues such as long steps of preconcentration and analysis [ 2 , 3 ]. In recent years, the development of biosensors has gained increasing interest due to their high sensitivity, selectivity, and accuracy [ 4 ]. The development of whole-cell and cell-free biosensors for the detection of heavy metals has raised increased interest.…”
Section: Introductionmentioning
confidence: 99%
“…The sensor was elaborated according to the method described by Touzi et al . [ 54 ]. In this study, we evaluated the applicability of the EPS as a sensitive membrane of gold wafers transducer.…”
Section: Methodsmentioning
confidence: 99%