2009
DOI: 10.1109/tie.2009.2019775
|View full text |Cite
|
Sign up to set email alerts
|

Detection Method for Open-Circuit Fault in Neutral-Point-Clamped Inverter Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 119 publications
(6 citation statements)
references
References 22 publications
0
6
0
Order By: Relevance
“…For each leg, there are six available current paths according to the current direction and corresponding switching state, as shown in Fig. 1b and summarised in Table 1 [19]. This figure shows that current paths 1, 2, 5 and 6 involve IGBTs, while current paths 3 and 4 use the freewheeling diodes.…”
Section: Analysis Of the 3lnpc Drive Under Normal And Faulty Conditionsmentioning
confidence: 99%
See 2 more Smart Citations
“…For each leg, there are six available current paths according to the current direction and corresponding switching state, as shown in Fig. 1b and summarised in Table 1 [19]. This figure shows that current paths 1, 2, 5 and 6 involve IGBTs, while current paths 3 and 4 use the freewheeling diodes.…”
Section: Analysis Of the 3lnpc Drive Under Normal And Faulty Conditionsmentioning
confidence: 99%
“…Identification of clamp-diode faults [19] steady state RL load no no no [14] steady state AC drive yes no yes [12] steady state RL load yes no no grid-connected yes no no [20] steady state grid-connected (cos j =1) no no no grid-connected (cos j = 0.5) yes no no [22] speed and torque transients AC drive yes no no this paper speed and torque transients AC drive yes yes yes…”
Section: Identification Of Double Faultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Tae-Jin et al [16] presented a diagnostic method for OC faults in 3LNPC inverters based on the comparison of the instantaneous voltage values measured between output terminals of each inverter leg and the DC bus middle point. This method has the disadvantage that it needs extra voltage sensors and only identifies the faulty phase.…”
Section: Wwwietdlorgmentioning
confidence: 99%
“…Switch fault diagnosis in multilevel inverters has been researched extensively [10][11][12][13][14][15][16][17][18][19][20]. In [15], the detection method is presented for the open-circuit failure in a standard NPC inverter. It requires sensors and a comparator circuit to measure pole voltage and its duration.…”