1973
DOI: 10.1016/s0035-2977(73)80073-2
|View full text |Cite
|
Sign up to set email alerts
|

Détection de chimères ABO sur Groupamatic* 360 GC

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

1973
1973
1978
1978

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…Our experience, based on 600,000 runs and associated with various experimental works [1] allows us to confirm the extremely high reliability of this system for automatic immunohematological reactions; we feel that determination of the ABO group is the best example, because here, more than anywhere else, no error should occur, be it while determining the group itself or during transmission of results.…”
mentioning
confidence: 64%
See 1 more Smart Citation
“…Our experience, based on 600,000 runs and associated with various experimental works [1] allows us to confirm the extremely high reliability of this system for automatic immunohematological reactions; we feel that determination of the ABO group is the best example, because here, more than anywhere else, no error should occur, be it while determining the group itself or during transmission of results.…”
mentioning
confidence: 64%
“…The principle and details of mode of operation of Groupamatic have already been published [1,3,[5][6][7][8] and we do not repeat them here; the reader interested in obtaining this information may contact the manufacturer. On the other hand, it is important to have a thorough understanding of the different principles which, provided the user observes the rules of classical serology, ensure the reliability of the determination.…”
Section: Methodsmentioning
confidence: 99%
“…The ratio of potentially dangerous donors in case of non-isogroup transfusion is 2.86% of the total number of screened donors. This detection is performed simultaneously with other immunohaematological and serological tests: ABO and Rh grouping, screening of irregular allo-antibodies, screening of syphilis.All immunohaematological tests concerning voluntary donors of the CNTS are performed on two Groupamatic® [4][5][6][7], We thus found it necessary to extend the automation up to the screening of so-called 'dangerous' donors whose blood units may not be transfused in an iso group fashion. This screening used to be made manually on all group O donors by a haemolytic test of Ax and B cells in presence of human complement, following the technique described by Mollison [8].…”
mentioning
confidence: 99%