Detection and location of interturn short circuits in the stator windings of operating motors

Abstract: Motors are critical components for electric utilities and process industries. A motor failure can result in the shutdown of a generating unit or production line, or require that redundant plant be utilized to circumvent the problem. One major cause of failures is breakdown of the tum insulation leading to puncture of the groundwall. Early detection of intertum shorts during motor operation would eliminate consequential damage to adjacent coils and the stator core reducing repair costs and motor outage time. In… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
113
0
4

Year Published

2012
2012
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 346 publications
(117 citation statements)
references
References 6 publications
0
113
0
4
Order By: Relevance
“…Unless detected early enough, it might lead to fire, explosion, and even loss of personnel [8]. It has been reported that a turn to turn short circuit results in a disruption of the magnetic field symmetry in the winding region of the machine as well as increasing the magnitudes of certain harmonic components [9]. Turn-to-turn faults are difficult to detect with confidence.…”
Section: Detection Of Short-circuit Faultmentioning
confidence: 99%
See 1 more Smart Citation
“…Unless detected early enough, it might lead to fire, explosion, and even loss of personnel [8]. It has been reported that a turn to turn short circuit results in a disruption of the magnetic field symmetry in the winding region of the machine as well as increasing the magnitudes of certain harmonic components [9]. Turn-to-turn faults are difficult to detect with confidence.…”
Section: Detection Of Short-circuit Faultmentioning
confidence: 99%
“…According to [9], the occurrence of a turn-to-turn fault results in a disruption of magnetic field symmetry in the end winding region of the machine as well as increasing the magnitudes of certain harmonic components. This is because there is a severe imbalance between the current flowing in the shorted turn and the corresponding diametrically opposite turn in the winding.…”
Section: Detection Of Short-circuit Faultmentioning
confidence: 99%
“…However, methods based on axial flux have two drawbacks that can weaken monitoring efficiency [19]. First, multiple probes with high concentricity must be installed at the end of the winding coil.…”
Section: Condition Monitoring Of Stators Of Pmsgsmentioning
confidence: 99%
“…4) Methods based on axial flux Faults can be detected through shaft voltage and axial magnetic flux leakage [19][20][21]. However, methods based on axial flux have two drawbacks that can weaken monitoring efficiency [19].…”
Section: Condition Monitoring Of Stators Of Pmsgsmentioning
confidence: 99%
See 1 more Smart Citation