2000
DOI: 10.1063/1.125603
|View full text |Cite
|
Sign up to set email alerts
|

Detection and analysis of early failures in electromigration

Abstract: The early failure issue in electromigration (EM) has been an unresolved subject of study over the last several decades. A satisfying experimental approach for the detection and analysis of early failures has not been established yet. In this study, a technique utilizing large interconnect arrays in conjunction with the well-known Wheatstone Bridge is presented. A total of more than 20 000 interconnects were tested. The results indicate that the EM failure mechanism studied here follows lognormal behavior down … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2001
2001
2022
2022

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 17 publications
(16 citation statements)
references
References 6 publications
0
16
0
Order By: Relevance
“…Previous work by Gall et al 20,21 has shown that the reliability of Albased interconnects does not show significant deviation from monomodal behavior down to nearly 1 part in 10 5 interconnects. In the case of DD Cu, the presence of two distinct interfacial flux divergence regions means that a bimodal distribution of failures may be an intrinsic characteristic of this technology.…”
Section: Cu Dd Versus Al(cu) Interconnectmentioning
confidence: 92%
See 1 more Smart Citation
“…Previous work by Gall et al 20,21 has shown that the reliability of Albased interconnects does not show significant deviation from monomodal behavior down to nearly 1 part in 10 5 interconnects. In the case of DD Cu, the presence of two distinct interfacial flux divergence regions means that a bimodal distribution of failures may be an intrinsic characteristic of this technology.…”
Section: Cu Dd Versus Al(cu) Interconnectmentioning
confidence: 92%
“…The presence of early failures in small amounts in an interconnect population would be undetectable in the small samplings (20 or so) typically used for EM testing. Gall et al 20,21,40 have shown a useful method by which "early" or "extrinsic failure" on a very large scale in Al(Cu) technology can be characterized. The method uses multiply linked chains of long interconnects to enhance the sensitivity of interconnect populations to early failures.…”
Section: Weakest Link Approximation and Failure Distributionsmentioning
confidence: 99%
“…4,5,7 A basic unit of five interconnects in parallel serves as the smallest building block. Figure 2 depicts a top and side view of this basic unit.…”
Section: Test Structuresmentioning
confidence: 99%
“…Previous short reports on this technique have been published. 4,5 The goals of the present study are the extension of the tested sample size, the characterization of the statistical EM behavior as a function of temperature, and the detailed description of the statistical analysis. Over a temperature range from 155 to 200°C, more than 75 000 interconnects were tested without any early failure occurrences.…”
Section: Introductionmentioning
confidence: 99%
“…Liu et al (2004) (Gall et al 1996;Gall et al 2000;Gall et al 2001) used the weakest link approach tested more than 75000 interconnects with 480…”
mentioning
confidence: 99%