Advances in Electronic Packaging, Parts A, B, and C 2005
DOI: 10.1115/ipack2005-73396
|View full text |Cite
|
Sign up to set email alerts
|

Design of Transducer and Package at the Same Time

Abstract: The early effort of MEMS sensor development was focused mainly on the transducer: designing and manufacturing a mechanical device that could convert a physical input into an electrical signal using traditional semiconductor processes. With the rapid advancement in MEMS technologies, MEMS packaging is becoming increasingly critical and plays a major role in the successful commercialization of a MEMS product. Freescale has adopted the philosophy [1–2] of concurrent transducer and package designs to facilitate th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2008
2008
2014
2014

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…Package stress simulations were used to determine substrate deformations which were applied to a finite element model of the transducer [10]. This technique was used to optimize the arrangement of fixed finger and proof mass anchors within the central region in what is effectively a combination of stress canceling and isolation.…”
Section: Design Featuresmentioning
confidence: 99%
“…Package stress simulations were used to determine substrate deformations which were applied to a finite element model of the transducer [10]. This technique was used to optimize the arrangement of fixed finger and proof mass anchors within the central region in what is effectively a combination of stress canceling and isolation.…”
Section: Design Featuresmentioning
confidence: 99%
“…The limitations unique to MAVs limit the choice of accelerometers to MEMS type, which has struggled to reach tactical grade (Dong et al, 2011) and more recently navigation grade (Keller, 2013). MEMS accelerometer's vulnerability to vibration and temperature variation has led to lower performance and reliability issues (Li et al, 2005, Sarihan et al, 2008. Packaging stresses due to temperature variation, humidity, and vibration can affect performance and increase the potential for sensor failures (Jian et al, 2011).…”
Section: Deficiencies Of Mems Accelerometersmentioning
confidence: 99%
“…FEA models are required for both package thermalmechanical performance and MEMS electrostatic-mechanical performance. Often the package models and MEMS models can be run separately and then numerically linked [3,4]. Figure 1 shows a cross-section of a typical accelerometer.…”
Section: Introductionmentioning
confidence: 99%
“…A further challenge is that the stress sensing die should be the same physical dimension as the MEMS die, this is because the MEMS die design has the significant effect on the package thermal-mechanical response. It is difficult to achieve the same form factor because not only must the die size be the same, but most MEMS capacitive acceleration die have wafer-level "caps" attached that form a two-die stack as shown in figure 1 [3]. A final problem is that the piezo-resistive effect relies on resistors with fairly large temperature coefficients, and this can complicate multi-temperature testing of packaged devices.…”
Section: Introductionmentioning
confidence: 99%