2019
DOI: 10.1016/j.apenergy.2018.12.030
|View full text |Cite
|
Sign up to set email alerts
|

Design of header and coil steam generators for concentrating solar power applications accounting for low-cycle fatigue requirements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(12 citation statements)
references
References 33 publications
(31 reference statements)
0
11
0
1
Order By: Relevance
“…Ferruzza et al proposed a design of header and coil steam generators for CSP applications in consideration of low‐cycle fatigue requirements, which can lower the pressure loss and reduce cost. [ 30 ] The results, which were validated by the parameters of real equipment, indicated that the calculated overall heat exchange area and the weight of the whole equipment differ from the actual by no more than 3.6%. González‐Gómez et al modeled the power block transient performance as a series of steady‐state simulations of different loads; however, the heat exchangers in the steam generator system were modeled by coupled transient thermodynamic and stress models to compute the stress.…”
Section: Steady‐state Characteristics Analyses Of Cspmentioning
confidence: 87%
See 1 more Smart Citation
“…Ferruzza et al proposed a design of header and coil steam generators for CSP applications in consideration of low‐cycle fatigue requirements, which can lower the pressure loss and reduce cost. [ 30 ] The results, which were validated by the parameters of real equipment, indicated that the calculated overall heat exchange area and the weight of the whole equipment differ from the actual by no more than 3.6%. González‐Gómez et al modeled the power block transient performance as a series of steady‐state simulations of different loads; however, the heat exchangers in the steam generator system were modeled by coupled transient thermodynamic and stress models to compute the stress.…”
Section: Steady‐state Characteristics Analyses Of Cspmentioning
confidence: 87%
“…[ 29 ] According to low fatigue requirement, Ferruzza et al showed that the optimized design parameters of the entire steam generator structure were given when water pressure loss was 0.1 MPa. [ 30 ] Through optimization, the equipment heating rate increased to 9.1 K min −1 , but the cost increased by 4.2%.…”
Section: Steady‐state Characteristics Analyses Of Cspmentioning
confidence: 99%
“…For a more comprehensive description of the header and coil geometry, the reader is referred to Ref. [18]. Such design has recently gained traction and interest in the industry.…”
Section: Introductionmentioning
confidence: 99%
“…400 °C. Parabolrinnen sind hierbei die kommerziell ausgereifteste Technologie solarthermischer Kraftwerke . Einzelne Module werden zu Kollektoren zusammengefasst und einachsig der Sonne nachgeführt.…”
Section: Introductionunclassified