2021
DOI: 10.1109/tim.2021.3106677
|View full text |Cite
|
Sign up to set email alerts
|

Design of Gradient Magnetic Field Coil Based on an Improved Particle Swarm Optimization Algorithm for Magnetocardiography Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 25 publications
(7 citation statements)
references
References 26 publications
0
6
0
Order By: Relevance
“…It is usually a multilayer magnetic shielding made of material with high permeability and suppresses the major stray magnetic field. The active components are compensation coils comprising triaxial uniform magnetic field coils and several gradient coils, which offset the remaining small part of the remnant magnetic induction [12,13].…”
Section: Introductionmentioning
confidence: 99%
“…It is usually a multilayer magnetic shielding made of material with high permeability and suppresses the major stray magnetic field. The active components are compensation coils comprising triaxial uniform magnetic field coils and several gradient coils, which offset the remaining small part of the remnant magnetic induction [12,13].…”
Section: Introductionmentioning
confidence: 99%
“…Triaxial uniform field coils are indispensable elements for the capture and manipulation of atoms in many quantum precision measurement devices. Examples of these devices include spin-exchange relaxation free (SERF) atomic magnetometers [1][2][3], nuclear magnetic resonance gyroscopes (NMRGs) [4], * Author to whom any correspondence should be addressed. magnetic resonance imaging devices [5,6], and atomic clocks [7].…”
Section: Introductionmentioning
confidence: 99%
“…Because of this problem, some researchers proposed the realization of in-situ measurement of the coil magnetic field using the atomic spin effect [18]. Zhang et al calibrated the coil magnetic field via extraction and analysis of the Larmor precession frequency of hyperpolarized 3 He in an atomic magnetometer [19]. Chen et al proposed acquisition of the coil magnetic field by measuring the π/2 pulse duration in an NMRG [4].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The gradient design methods can be divided into two categories depending on whether the coil is discrete [18] or distributed [19]- [23]. The distributed winding method is more flexible because the coil shapes do not need to be predetermined.…”
Section: Introductionmentioning
confidence: 99%