2008
DOI: 10.12989/scs.2008.8.3.231
|View full text |Cite
|
Sign up to set email alerts
|

Design of corrugated sheets exposed to fire

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…Previous studies have recommended an average holding time of two to three hours for the compression moulding of hybrid composites containing natural fibers. This also helps natural fibers function as a potential composite reinforcement [14]. Therefore, after 3 h of holding period, the manufactured PTGE based SCSP were extracted from the mould cavity.…”
Section: Fabrication Of Ptge Based Scspmentioning
confidence: 99%
See 1 more Smart Citation
“…Previous studies have recommended an average holding time of two to three hours for the compression moulding of hybrid composites containing natural fibers. This also helps natural fibers function as a potential composite reinforcement [14]. Therefore, after 3 h of holding period, the manufactured PTGE based SCSP were extracted from the mould cavity.…”
Section: Fabrication Of Ptge Based Scspmentioning
confidence: 99%
“…Due to these attributes, the lattice structure has excellent application potential. However, industrialising raw materials (particularly carbon fibres) and complex preparation processes is more expensive and difficult [14]. The design of materials and structures is not only concerned with performance but also ensures effective cost management [15].…”
Section: Introductionmentioning
confidence: 99%
“…Four sets of experiments have been performed. In 2005, two sets of tests were carried out [2]. In set A, E-VS BOHR 5-5.5×38 screws and a sealed washer AE19 mm were used.…”
Section: Experiments With Screwed Connectionsmentioning
confidence: 99%
“…Researches [1,5] have revealed that failures normally do not take place in the screw connector itself. So the following assumptions are made in the analysis: the screw connector has the higher strength and rigidity than other materials in the connection assembly.…”
Section: Materials Modelingmentioning
confidence: 99%
“…It has been shown from researches [1,2] that axial forces can often be generated in steel deck when the roof sheeting is loaded transversely and is connected to purlin or directly to the trusses with screw fasteners, in fire. Due to the restraints to thermal expansion these forces are initially compressive.…”
Section: Introductionmentioning
confidence: 99%