2013
DOI: 10.1016/j.medengphy.2013.03.012
|View full text |Cite
|
Sign up to set email alerts
|

Design of an implantable seismic sensor placed on the ossicular chain

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
22
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(22 citation statements)
references
References 13 publications
0
22
0
Order By: Relevance
“…Most current hearing devices use microphones that are sensitive to sound pressure levels ranging from around 30 to 140 dB SPL [ 35 ], which matches this dynamic range. Considering that the sensitivity of human hearing is a function of frequency, the input range has also been defined from 30 to 100 phon [ 23 ], what equals 30 and 100 dB SPL at 1 kHz respectively. In general, the lower limit of the sensor’s dynamic range is defined by the sensor’s internal noise, while the superior limit marks the beginning of significant distortions/non-linearities of the sensor.…”
Section: Hearing Devices General Sensor Requirements and Sensor Perfomentioning
confidence: 99%
See 4 more Smart Citations
“…Most current hearing devices use microphones that are sensitive to sound pressure levels ranging from around 30 to 140 dB SPL [ 35 ], which matches this dynamic range. Considering that the sensitivity of human hearing is a function of frequency, the input range has also been defined from 30 to 100 phon [ 23 ], what equals 30 and 100 dB SPL at 1 kHz respectively. In general, the lower limit of the sensor’s dynamic range is defined by the sensor’s internal noise, while the superior limit marks the beginning of significant distortions/non-linearities of the sensor.…”
Section: Hearing Devices General Sensor Requirements and Sensor Perfomentioning
confidence: 99%
“…For example, sensitivity of common electret condenser microphones (ECM), with a 2.5 mm diameter membrane, used in conventional hearing aids, varies from 20 to 30 dB ref 1 mV/Pa [ 6 , 35 , 38 ]. Whereas the sensitivity of a piezoresistive MEMS accelerometer has been reported as mere 6 dB [ 16 , 39 ], and for capacitive sensors varied from − 9 to 30 dB [ 20 , 23 , 40 ]. Similarly, ECM’s EIN may be as low as 20 dB SPL at 1 kHz [ 7 ], whereas a capacitive accelerometer implanted in the middle ear may detect only SPL above 35 dB at the same frequency [ 21 ], and yet a piezoresistive accelerometer’s EIN may be 60 dB SPL at 1 kHz [ 16 ].…”
Section: Hearing Devices General Sensor Requirements and Sensor Perfomentioning
confidence: 99%