2001
DOI: 10.1002/1521-4109(200103)13:3<229::aid-elan229>3.0.co;2-3
|View full text |Cite
|
Sign up to set email alerts
|

Design of a Multilayer Cholesterol Amperometric Biosensorfor Preparation and Use in Flow Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0

Year Published

2003
2003
2015
2015

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(17 citation statements)
references
References 36 publications
(40 reference statements)
0
17
0
Order By: Relevance
“…An alternative method of determination of cholesterol is amperometric enzyme electrodes which allow rapid, accurate, low-cost and sensitive analysis. 3,12 Various types of amperometric enzyme electrodes have been reported for free cholesterol determination. Vol.…”
Section: Introductionmentioning
confidence: 91%
See 1 more Smart Citation
“…An alternative method of determination of cholesterol is amperometric enzyme electrodes which allow rapid, accurate, low-cost and sensitive analysis. 3,12 Various types of amperometric enzyme electrodes have been reported for free cholesterol determination. Vol.…”
Section: Introductionmentioning
confidence: 91%
“…38,50 In cholesterol biosensors, poly(o-phenylenediamine) films were also used for elimination interference and determination of cholesterol in human serum could not be performed by using prepared biosensor. 12,51 However, in the present study, poly(ophenylenediamine) film is composed both permselective membrane and immobilization matrix for enzyme.…”
Section: (1)mentioning
confidence: 99%
“…The detection limit calculated using the standard equation (3s/sensitivity) and was found to be 1 Â 10 À16 M, where s is standard deviation of the electrode without hybridization. 41 The comparison of response characteristics of EPD-PANI-Au nanocomposite with other PANI based nanocomposites reported in literature for nucleic acid detection shows that this sensor exhibits higher linear range, sensitivity and stability (as shown in Table 2). (Fig.…”
Section: Genosensor Response Studiesmentioning
confidence: 99%
“…However, the sensing current of DA was higher than that of AA which has a lower oxidized potential. It is because some carbons on the polymer backbone was over-oxidized and transformed into carboxylic groups at a high potential when polymerization (Cosnier, 2003;Vidal et al, 2001). In the literature (Palmisano et al, 1995), the carboxylic groups on the over-oxidized conducting polymer, polypyrrole, were proved by X-ray photoelectron spectroscopy (XPS).…”
Section: The Interferences Effect and Monitoring Of Real Samplementioning
confidence: 99%