2003
DOI: 10.1061/(asce)1090-025x(2003)7:4(264)
|View full text |Cite
|
Sign up to set email alerts
|

Design, Construction, and Operation of Tailored Permeable Reactive Barriers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2004
2004
2020
2020

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(10 citation statements)
references
References 2 publications
0
10
0
Order By: Relevance
“…All solutions receiving ions (except for column S2B) were adjusted to a neutral pH value of 7 by addition of hydrochloric acid; the pH 9 of the feed solution for column S2B was adjusted by addition of potassium hydroxide. Columns were filled with 150 g granulated cast iron (nominal grain size 300-2000 μm, Gotthart Maier, Germany) which has been used in a number of laboratory investigations (Ebert et al, 2006;O et al, 2009;Rosenthal et al, 2004;Van Nooten et al, 2007) and field applications (Birke et al, 2003a(Birke et al, , 2003b. Column S2S (75 g) and column S2L (270 g) contained different amounts for elucidation of the relative influence of column length.…”
Section: Materials Methods and Calculationsmentioning
confidence: 99%
“…All solutions receiving ions (except for column S2B) were adjusted to a neutral pH value of 7 by addition of hydrochloric acid; the pH 9 of the feed solution for column S2B was adjusted by addition of potassium hydroxide. Columns were filled with 150 g granulated cast iron (nominal grain size 300-2000 μm, Gotthart Maier, Germany) which has been used in a number of laboratory investigations (Ebert et al, 2006;O et al, 2009;Rosenthal et al, 2004;Van Nooten et al, 2007) and field applications (Birke et al, 2003a(Birke et al, , 2003b. Column S2S (75 g) and column S2L (270 g) contained different amounts for elucidation of the relative influence of column length.…”
Section: Materials Methods and Calculationsmentioning
confidence: 99%
“…Treatment walls are structures installed underground to treat the contaminated groundwater found at hazardous waste sites (Suthersan, 1997;Birke et al, 2003;Baciocchi et al, 2003). Treatment walls rely on the natural movement of water to carry the contaminants through the wall structure (Nyer, 1996).…”
Section: Passive/reactive Treatment Wallsmentioning
confidence: 99%
“…Target contaminant groups for passive treatment walls are VOCs, SVOCs, and inorganics (FRTR, 1999c). The specific filling chosen for the wall is based on the contaminant found at the site (RAAG, 2000;Birke et al, 2003). Guerin et al (2002) have discussed an interesting application of reactive barrier technology to petroleum hydrocarbon contaminated groundwater.…”
Section: Passive/reactive Treatment Wallsmentioning
confidence: 99%
“…However, reports available detail a PRB containing peat for the removal of petroleum hydrocarbons (n-alkanes and BTEX) by sorption and aerobic biodegradation processes in Southeast Australia (11) and a PRB containing aerated sand at a FMGP site in Portadown, Northern Ireland (12). A PRB for the removal of PAH and BTEX by sorption onto granular activated carbon (GAC) has also been installed in Germany (13).…”
Section: Introductionmentioning
confidence: 99%