Design and processing of near-β Ti–Nb–Ag alloy with low elastic modulus and enhanced corrosion resistance for orthopedic implants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(4 citation statements)
references
References 77 publications
2
2
0
Order By: Relevance
“…Following this investigation, two R-CPE element ECMs ( R s (CPE dl ( R ct (CPE f R f )))) were implemented to simulate the measured EIS data of the CuNi-coated SS specimens, as shown in Figure b. Here, the time constant at higher frequencies is accompanied by the R ct and the double-layer capacitance ( C dl ) of the electrochemical reactions at the passive film/electrolytic interface, whereas the time constant at a lower frequency (CPE f R f ) is due to the passive film. , The simulated data agreed well with the experimentally obtained results and the values of chi-squared (χ 2 ) (10 –4 ∼ 10 –5 ), suggesting that the two nominated ECMs evidently replicate the definite electrochemical reactions taking place on the investigated SS specimens in the PEM-FC simulated conditions Table summarizes the EIS circuit values obtained from the ECM fitting analysis.…”
Section: Resultssupporting
confidence: 80%
See 1 more Smart Citation
“…Following this investigation, two R-CPE element ECMs ( R s (CPE dl ( R ct (CPE f R f )))) were implemented to simulate the measured EIS data of the CuNi-coated SS specimens, as shown in Figure b. Here, the time constant at higher frequencies is accompanied by the R ct and the double-layer capacitance ( C dl ) of the electrochemical reactions at the passive film/electrolytic interface, whereas the time constant at a lower frequency (CPE f R f ) is due to the passive film. , The simulated data agreed well with the experimentally obtained results and the values of chi-squared (χ 2 ) (10 –4 ∼ 10 –5 ), suggesting that the two nominated ECMs evidently replicate the definite electrochemical reactions taking place on the investigated SS specimens in the PEM-FC simulated conditions Table summarizes the EIS circuit values obtained from the ECM fitting analysis.…”
Section: Resultssupporting
confidence: 80%
“…35,36 The simulated data agreed well with the experimentally obtained results and the values of chi-squared (χ 2 ) (10 −4 ∼ 10 −5 ), suggesting that the two nominated ECMs evidently replicate the definite electrochemical reactions taking place on the investigated SS specimens in the PEM-FC simulated conditions. 37 Table 3 summarizes the EIS circuit values obtained from the ECM fitting analysis. The comparison of the CPE dl and R ct values in various environments (OCP, anode, and cathode) indicates that the coated SS304 had higher corrosion resistance at each potential.…”
Section: Electrochemical Corrosion Test Onmentioning
confidence: 99%
“…In Figure 2c is presented the results of Ti-40Nb. It was observed the same tendence that it was observed in 15 and 25 Nb and the found results are in accordance with literature 28 . However, it may be explained by other mechanism since the 40Nb did not present α phase.…”
Section: Ti-15nbsupporting
confidence: 92%
“…Niobium is a β stabilizer, so that the amount of niobium can be adjusted to produce (α+β) or β type alloys 9,11,12 . By adding Nb, Ti alloys with higher corrosion resistance [13][14][15] , lower Young's modulus 9,14,16 and even superelasticity and shape memory properties 17,18 can be achieved.…”
Section: Introductionmentioning
confidence: 99%