2004
DOI: 10.1016/j.physb.2004.03.219
|View full text |Cite
|
Sign up to set email alerts
|

Design and performance of a two-dimensional multi-wire neutron detector with a sensitive area of 50×50cm2 and a spatial resolution of ∼2×2mm2

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2006
2006
2018
2018

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 5 publications
0
4
0
Order By: Relevance
“…Horizontally, the beam divergence was < 0.1 • . The two-dimensional position sensitive detector [35] provides a spatial resolution of 2.7 mm × 2.7 mm. As polarizing device a transportable NSF filling pressure p = 1.06 ± 0.01 bar was inserted into the neutron beam ahead of the sample and was replaced every two to three days.…”
Section: Methodsmentioning
confidence: 99%
“…Horizontally, the beam divergence was < 0.1 • . The two-dimensional position sensitive detector [35] provides a spatial resolution of 2.7 mm × 2.7 mm. As polarizing device a transportable NSF filling pressure p = 1.06 ± 0.01 bar was inserted into the neutron beam ahead of the sample and was replaced every two to three days.…”
Section: Methodsmentioning
confidence: 99%
“…According to a literature survey, the latest contributions are from German, Russian, Hungarian and American scientists concerning increasing neutron detector's sensitive area with good position resolution or high detecting efficiency, increasing the counting rate, improving the gas purity, developing curved 2D position-sensitive neutron detectors, and developing readout electronics and software modules, etc. [6,[10][11][12][13][14][15][16][17]. In addition, the recent MILAND project with most European MWPC developers was devoted to the development of a new detector with large sensitive area, high counting rate and good position resolution.…”
Section: Current Status Of Detector Development and This Study's Sign...mentioning
confidence: 99%
“…A 2-dimensional, 3 He detector (Denex GmbH) will be mounted on these motion stages, which measures the neutron location using the delay-line technique [40]. The large active area of the detector (500 mm wide £ 250 mm wide) will enable the collection of the specular reflectivity signal, off-specular scattering, as well as contributions to the background signal.…”
Section: The Detector Vesselmentioning