2021
DOI: 10.15294/jte.v13i2.31884
|View full text |Cite
|
Sign up to set email alerts
|

Design and Implementation of Z-Source Inverter by Simple Boost Control Technique for Laboratory Scale Micro-Hydro Power Plant Application

Abstract: In a power plant such as micro-hydropower (MHP), an induction generator (IG) is usually employed to produce electrical power. Therefore, an inverter is needed to deliver it with high efficiency. Z-source inverter (ZSI) has been introduced as a topology with many advantages over conventional inverters. This research aims to investigate the performance of ZSI based simple boost control (SBC) in laboratory-scale MHP systems using a rewinding induction generator. This research has been conducted both from simulati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 30 publications
(42 reference statements)
0
8
0
Order By: Relevance
“…The voltage on the load side is larger than the PV voltage in solar harvesting energy applications. It implies that the step-up voltage procedure must be carried out, and the boost converter becomes one of the several topologies that may be chosen and included into an MPPT [32], [36], [55], [58], [78], [81], [82], [93], [102], [103], [110], [132], [135], [258], [264], [276], [278], [286]- [300]. The boost converter is the most popular option, and it has been manufactured by industry [295].…”
Section: Boost Convertermentioning
confidence: 99%
See 1 more Smart Citation
“…The voltage on the load side is larger than the PV voltage in solar harvesting energy applications. It implies that the step-up voltage procedure must be carried out, and the boost converter becomes one of the several topologies that may be chosen and included into an MPPT [32], [36], [55], [58], [78], [81], [82], [93], [102], [103], [110], [132], [135], [258], [264], [276], [278], [286]- [300]. The boost converter is the most popular option, and it has been manufactured by industry [295].…”
Section: Boost Convertermentioning
confidence: 99%
“…The Z-source comprises two identical inductors and two capacitors, in which the modernization of this configuration has been fluent and conducted to achieve better performance [87], [102], [122], [166], [291], [300], [314], [366]- [368]. A modified Z-source DC-DC converter is proposed by [367].…”
Section: Z-source Convertermentioning
confidence: 99%
“…There are much research concerning the control of ZSI and its improvement. [9][10][11][12][13] In Dave et al, 9 the online parametric investigation has been achieved using online condition monitoring the investigation of this parameter can help to predict the maximum system life span. However, the control method did not give any methodology for the compensation transfer function.…”
Section: Introductionmentioning
confidence: 99%
“…Planning in saving the budget can be applied to a design. Moreover, optimization can be used to an appropriate model design [1]. Accurate design plays an essential role in the development of control systems knowledge.…”
Section: Introductionmentioning
confidence: 99%