2013
DOI: 10.1016/j.nima.2012.10.004
|View full text |Cite
|
Sign up to set email alerts
|

Design and characterization of the beam monitor detectors of the Italian National Center of Oncological Hadron-therapy (CNAO)

Abstract: A new hadron-therapy facility implementing an active beam scanning technique has been developed at the italian National Center of Oncological Hadron-therapy (CNAO). This paper presents the design and the characterization of the beam monitor detectors developed for the online monitoring and control of the dose delivered during a treatment at CNAO. The detectors are based on five parallel-plate transmission ionization chambers with either a single large electrode or electrodes segmented in 128 strips (strip cham… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
34
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 35 publications
(34 citation statements)
references
References 13 publications
0
34
0
Order By: Relevance
“…In particular, 2‐D arrays of ICs have been developed to accurately and efficiently verify the 1D dose profiles, the planar dose, the 3D dose distributions and also as beam monitors . Their main disadvantage is the relatively low spatial resolution (5–8 mm distance between sensors) compared with films, or scintillating screens.…”
Section: Detectors For Absorbed Dose In Nonreference Conditionsmentioning
confidence: 99%
See 1 more Smart Citation
“…In particular, 2‐D arrays of ICs have been developed to accurately and efficiently verify the 1D dose profiles, the planar dose, the 3D dose distributions and also as beam monitors . Their main disadvantage is the relatively low spatial resolution (5–8 mm distance between sensors) compared with films, or scintillating screens.…”
Section: Detectors For Absorbed Dose In Nonreference Conditionsmentioning
confidence: 99%
“…The layout of such devices depends on the required spatial resolution and on the total area to be covered. In particular, strip chambers usually provide higher resolution (<100 μm) and faster (20 kHz) beam position evaluation compared with pixel chambers (>200 μm and 5 kHz) with the same sensitive area …”
Section: Detectors For Beam Monitoringmentioning
confidence: 99%
“…For the measurements presented in this paper, the gain was fixed to a charge quantum of 200 fC, a setting commonly used in clinical applications [8]. It was shown [9] that this gain is fairly uniform across the channels, with a channel-to-channel variation of 1.28% rms.…”
Section: Methodsmentioning
confidence: 99%
“…In this paper we present a simple and effective solution to increase by almost two orders of magnitude the input current range of an Application Specific Integrated Circuit (ASIC) which was designed by our group and used in several laboratories worldwide [6][7][8], still maintaining a good performance in terms of noise and resolution. The chip, named TERA, implements an architecture based on a charge-to-count converter and integrates 64 equal channels.…”
Section: Introductionmentioning
confidence: 99%
“…CNAO is an Italian hospital-based facility using a synchrotron to accelerate proton and carbon ion beams [15-17]. Spill-to-spill capability of beam energy variation, as well as pencil beam scanning in the transversal plane, are provided as full 3-D active dose delivery modality.…”
Section: Methodsmentioning
confidence: 99%