2015
DOI: 10.1016/j.nima.2015.07.013
|View full text |Cite
|
Sign up to set email alerts
|

A simple method to increase the current range of the TERA chip in charged particle therapy applications

Abstract: a b s t r a c tThe development of the next generation of accelerators for charged particle radiotherapy aims to reduce dimensions and operational complexity of the machines by engineering pulsed beams accelerators. The drawback is the increased difficulty to monitor the beam delivery. Within each pulse, instantaneous currents larger by two to three orders of magnitude than present applications are expected, which would saturate the readout of the monitor chambers. In this paper, we report of a simple method to… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 8 publications
0
3
0
Order By: Relevance
“…An attempt to increase the current range of the existing front-end readout has been done by Cirio et al 174 Exploiting the availability of several readout channels in the TERAchip ASIC, 168 the proposed method evenly splits the input current from a detector element into several readout channels and adds up all the counts of these readout channels to reconstruct the input current. Such an arrangement allows to extend the input current range proportionally to the number of channels used, and the good linearity observed for each channel individually is preserved.…”
Section: E1 Limitations Of Present Equipmentmentioning
confidence: 99%
See 1 more Smart Citation
“…An attempt to increase the current range of the existing front-end readout has been done by Cirio et al 174 Exploiting the availability of several readout channels in the TERAchip ASIC, 168 the proposed method evenly splits the input current from a detector element into several readout channels and adds up all the counts of these readout channels to reconstruct the input current. Such an arrangement allows to extend the input current range proportionally to the number of channels used, and the good linearity observed for each channel individually is preserved.…”
Section: E1 Limitations Of Present Equipmentmentioning
confidence: 99%
“…An attempt to increase the current range of the existing front‐end readout has been done by Cirio et al . Exploiting the availability of several readout channels in the TERAchip ASIC, the proposed method evenly splits the input current from a detector element into several readout channels and adds up all the counts of these readout channels to reconstruct the input current.…”
Section: Detectors For Beam Monitoringmentioning
confidence: 99%
“…The readout system used is based on the TERA08 integrated circuit, designed for medical applications by the INFN group of Torino [28]. Initially developed as a front-end electronic readout for gas monitor chambers, TERA08 performs a conversion from the instantaneous current to a digital pulse frequency, where each digital pulse corresponds to a fixed input charge quantum.…”
Section: Tera08 Front-endmentioning
confidence: 99%