Design and characterization of a real-time, wearable, endosomatic electrodermal system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(20 citation statements)
references
References 36 publications
0
19
0
Order By: Relevance
“…In contrast, the Obimon utilizes a 22-bit resolution A/D converter with very low noise specification (MCP3551/3) eliminating the need for complex preamplification or filtering, nor is it needed to subtract an estimated SCL value before analog-to-digital conversion, further improving the precision of measurements. For comparison, several small footprint EDA devices use 10-or 12-bit resolution (e.g., Affanni & Chiorboli, 2015;Boquete et al, 2012;Kappeler-Setz, Gravenhorst, Schumm, Arnrich, & Tröster, 2013;Poh et al, 2010;Savić & Geršak, 2015;Schmidt et al, 2016). The difference in resolution is from 100 to 1,000 times.…”
Section: System Design Of the Tested Device And Measurement Detailsmentioning
confidence: 99%
“…In contrast, the Obimon utilizes a 22-bit resolution A/D converter with very low noise specification (MCP3551/3) eliminating the need for complex preamplification or filtering, nor is it needed to subtract an estimated SCL value before analog-to-digital conversion, further improving the precision of measurements. For comparison, several small footprint EDA devices use 10-or 12-bit resolution (e.g., Affanni & Chiorboli, 2015;Boquete et al, 2012;Kappeler-Setz, Gravenhorst, Schumm, Arnrich, & Tröster, 2013;Poh et al, 2010;Savić & Geršak, 2015;Schmidt et al, 2016). The difference in resolution is from 100 to 1,000 times.…”
Section: System Design Of the Tested Device And Measurement Detailsmentioning
confidence: 99%
“…The feedback loop composed of the amplifier and the DC compensation block acts as a high-pass filter with cut-off frequency (2I) -1 , the chosen coincident with (2L) -1 =0.05 Hz. In this way, all the DC non-idealities of the amplifier (offset voltage, bias current, offset current) are removed by the DC compensation block [10].…”
Section: Analogue Front End Descriptionmentioning
confidence: 99%
“…Several bio-signals are measured while the subjects of such studies are doing tasks e.g. photoplethysmogram (PPG) [1], electroencephalogram (EEG) [2], electromyogram (EMG) [3], electrocardiogram (ECG) [4], [5], electrodermal activity (EDA) [6]- [10], and many others.…”
Section: Introductionmentioning
confidence: 99%
“…These systems are being developed for the monitoring of a variety of physiological signals to inform doctors or to raise an alarm in case of abnormalities or danger, e.g. body posture and falls monitoring [6,7], cardiovascular related signals [6,8], respiratory problems [6], thermal comfort [9], temporal pattern of perspiration [10], skin temperature [11], or mental stress via skin conductance [12].…”