2016
DOI: 10.18004/mem.iics/1812-9528/2016.014(03)07-013
|View full text |Cite
|
Sign up to set email alerts
|

Desempeño del Kit ELISA Chagas IICS V.1 para el diagnóstico de la enfermedad de Chagas

Abstract: En Paraguay, el tamizaje serológico para la enfermedad de Chagas en bancos de sangre es necesario, por lo cual es importante un método diagnóstico con alta sensibilidad. El ELISA Chagas test IICS V.1 es un ELISA indirecto sensibilizados con antígeno soluble de epimastigote de T.cruzi de la cepa Ypsilon. El objetivo del presente trabajo fue evaluar el desempeño del ELISA Chagas test IICS V.1 en comparación con kits comerciales, ademásanalizar los resultados de la evaluación externa e interna de calidad del kit.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
7
0
4

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(12 citation statements)
references
References 7 publications
1
7
0
4
Order By: Relevance
“…Regarding the results of the kappa index, a study which evaluated the reproducibility of serological tests for the diagnosis of T. cruzi infection in pregnant women in an endemic area of Santander (Colombia) reported a kappa index for the total ELISA tests performed in serum of 0.98 (IC95 % = 0.93-1.00) compared to the reference test 24 , which was a lower value than that reported in the present study. The same occurs when comparing our results with a study performed in Paraguay, where excellent agreement was obtained between the ELISA Chagas test IICS V.1 and the commercial kits: Chagatest ELISA-Wiener (κ = 0.89; IC95 % = 0.76-1) and ELISA test for Chagas III-Grupo BiosChile (κ = 0.92; IC95 % = 0.82-1) 25 .…”
Section: Discussionsupporting
confidence: 87%
“…Regarding the results of the kappa index, a study which evaluated the reproducibility of serological tests for the diagnosis of T. cruzi infection in pregnant women in an endemic area of Santander (Colombia) reported a kappa index for the total ELISA tests performed in serum of 0.98 (IC95 % = 0.93-1.00) compared to the reference test 24 , which was a lower value than that reported in the present study. The same occurs when comparing our results with a study performed in Paraguay, where excellent agreement was obtained between the ELISA Chagas test IICS V.1 and the commercial kits: Chagatest ELISA-Wiener (κ = 0.89; IC95 % = 0.76-1) and ELISA test for Chagas III-Grupo BiosChile (κ = 0.92; IC95 % = 0.82-1) 25 .…”
Section: Discussionsupporting
confidence: 87%
“…Regarding serological methods, 96% sensitivity and 99% specificity levels have been estimated for screening ELISA assays (38). Specifically for the Chagas III ELISA kit from the BiosChile Group an 82% to 99% specificity and a 99% sensitivity have been reported (39,40), and the test has also shown an excellent concordance with other ELISA tests, such as the Chagas test IIC V.1 (Research Institute in Health Sciences at Universidad Nacional de Asunción, Paraguay) and the Chagatest ELISA (Wiener) (40), with a kappa index of 0.92. However, in aboriginal communities in the Venezuelan States of Bolívar and Delta Amacuro, the ELISA Chagas III (BiosChile) method had a poor performance in detecting specific T. cruzi-IgG antibodies (41).…”
Section: Discussionmentioning
confidence: 96%
“…El porcentaje de sensibilidad (97,73 %) del UMELISA CHAGAS ® con la incorporación de estos antígenos en la fase sólida, fue similar al reportado por investigadores colombianos con los estuches comerciales Bioelisa CHAGAS ® , Chagatest ELISA recombinante ® , versión 3.0, Chagatest HAI ® y SD BIOLINE CHAGAS Ab Rapid ® en su estudio de comparación de la capacidad diagnóstica de siete métodos de determinación de la infección por T. cruzi en pacientes con enfermedad de Chagas crónica, en el cual obtuvieron valores de sensibilidad entre 95 y 98 % (23). En evaluaciones del kit ELISA Chagas IICS ® , versión 1 (24,25), se reportaron resultados similares al obtenido por nuestro grupo de trabajo con la nueva modificación de la fase sólida.…”
Section: Sensibilidad Y Especificidad Clínicasunclassified
“…Para determinar la especificidad clínica, se evaluaron muestras negativas provenientes de regiones endémicas de la enfermedad y muestras de donantes cubanos de sangre supuestamente sanos, dado que la enfermedad no existe hoy en Cuba. La especificidad del UMELISA CHAGAS ® fue de 99,33 % (IC 95% 98,88-99,78) y en otras pruebas se han reportado resultados similares (24)(25)(26)(27).…”
Section: Sensibilidad Y Especificidad Clínicasunclassified
See 1 more Smart Citation