2011
DOI: 10.1016/j.ijom.2011.09.009
|View full text |Cite
|
Sign up to set email alerts
|

Depth deviation and occurrence of early surgical complications or unexpected events using a single stereolithographic surgi-guide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
45
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 57 publications
(46 citation statements)
references
References 12 publications
1
45
0
Order By: Relevance
“…Therefore, the better results obtained in the present study were probably due to the fact that an extraoral radiopaque marker had been used, namely a well-defined geometric device in which a total of 300,000 points were scanned and overlapped during the matching procedure within the planning software, allowing a greater accuracy in the superimposition of the DICOM data and radiological stent as compared to standard protocols in which only a limited number of reference points are used. Furthermore, most of the studies contemplated a double scanning procedure, in which both the patient and the radiological template were subjected to a CT scan [36,39,40]. In contrast, in the present study, the radiological stent underwent an optical scan, providing STL data that, unlike with the CT scan, did not depend on the Hounsfield unit threshold based on the grey-level segmentation defined by the radiologist.…”
Section: Discussionmentioning
confidence: 93%
See 1 more Smart Citation
“…Therefore, the better results obtained in the present study were probably due to the fact that an extraoral radiopaque marker had been used, namely a well-defined geometric device in which a total of 300,000 points were scanned and overlapped during the matching procedure within the planning software, allowing a greater accuracy in the superimposition of the DICOM data and radiological stent as compared to standard protocols in which only a limited number of reference points are used. Furthermore, most of the studies contemplated a double scanning procedure, in which both the patient and the radiological template were subjected to a CT scan [36,39,40]. In contrast, in the present study, the radiological stent underwent an optical scan, providing STL data that, unlike with the CT scan, did not depend on the Hounsfield unit threshold based on the grey-level segmentation defined by the radiologist.…”
Section: Discussionmentioning
confidence: 93%
“…In particular, Di Giacomo et al [13] found an implant axis deviation within 7.25°±2.67°; the differences in distance between the planned and the placed positions at the implant shoulder were 1.45±1.42 mm, and 2.99±1.77 mm at the implant apex; further, Ozan et al [37] and Ersoy et al [23] showed higher deviations, as listed before. According to Cassetta et al [39], it was found that the use of three osteosynthesis screws, placed in a tripod formation, was sufficient to provide the necessary stability, thereby improving the system accuracy. Furthermore, unlike bone screws, bone pins were guided into dedicated sleeves with a limited planned depth, in order to prevent surgical template deformations caused by excessive fixing pressures.…”
Section: Discussionmentioning
confidence: 99%
“…3,5,6,[10][11][12][13] With CT, bone density measurements are given in HU based on density values for air (-1,000 HU) and pure water (0 HU). 3,5,6,[10][11][12][13] With CT, bone density measurements are given in HU based on density values for air (-1,000 HU) and pure water (0 HU).…”
Section: The Relationship Between Cbct-and Ct-based Gray Density Valumentioning
confidence: 99%
“…4 Several studies have proposed a variety of methods for assessing bone density, but these involve evaluation either at the time of implant site preparation or subsequent to implant placement. 3,5,6 Even more recently, due to the need for less expensive image acquisition protocols or for scanners with lower radiation dose, cone beam CT (CBCT) has been widely employed for oral and maxillofacial imaging, 7 as it seems to provide good spatial resolution, gray density range, and contrast, as well as a good pixel/noise ratio. 3,5,6 Even more recently, due to the need for less expensive image acquisition protocols or for scanners with lower radiation dose, cone beam CT (CBCT) has been widely employed for oral and maxillofacial imaging, 7 as it seems to provide good spatial resolution, gray density range, and contrast, as well as a good pixel/noise ratio.…”
Section: Introductionmentioning
confidence: 99%
“…The quality, quantity, and density of the jaw are important factors in implant treatment (3). Besides, mechanical characteristics are an important factor in Osseo integration and primary stability of the implant (48). Accurate information of bone structure will help the clinician to select the proper site, treatment plan, and surgical procedure for implant surgery (9).…”
Section: Introductionmentioning
confidence: 99%