Accuracy of densitometry of two cone beam computed tomography equipment in comparison with computed tomography

Abstract: BackgroundThe use of oral implants has been growing, and cone beam computerized tomography (CBCT) has become the method of choice for oral and maxillofacial radiology.ObjectiveTo assess the accuracy of bone densitometry in two different CBCT devices in comparison with MDCT (multi-detector CT).MethodsDifferent concentrations of urografin, including 2.5%, 5%, 7.5%, 10%, 12.5%, were prepared, and the Hounsfield unit of these solution was measured by two CBCT devices (SORDEX CRANEX 3D and NEWTOM 5G) and one spiral… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 15 publications
0
6
0
Order By: Relevance
“…The bone quality, mainly manifested by the bone mineral density (BMD), can be assessed in CT scans by measurements the number of Hounsfield units (HU), and there is a linear relationship between gray scales between the GV in CBCT and the HU in CT (Razi, Niknami, & Alavi Ghazani, ; Valiyaparambil et al, ). It is worth mentioning that the intensity of the GV in a CBCT imaging system could be affected by scatter radiation (Cassetta, Stefanelli, Carlo, Pompa, & Barbato, ; Haghanifar et al, ; Kim, ). Several technique parameters could affect scatter radiation, including the FOV, voltage, exposure time, electron flow, and the resolution (Naitoh, Hirukawa, Katsumata, & Ariji, ).…”
Section: Discussionmentioning
confidence: 99%
“…The bone quality, mainly manifested by the bone mineral density (BMD), can be assessed in CT scans by measurements the number of Hounsfield units (HU), and there is a linear relationship between gray scales between the GV in CBCT and the HU in CT (Razi, Niknami, & Alavi Ghazani, ; Valiyaparambil et al, ). It is worth mentioning that the intensity of the GV in a CBCT imaging system could be affected by scatter radiation (Cassetta, Stefanelli, Carlo, Pompa, & Barbato, ; Haghanifar et al, ; Kim, ). Several technique parameters could affect scatter radiation, including the FOV, voltage, exposure time, electron flow, and the resolution (Naitoh, Hirukawa, Katsumata, & Ariji, ).…”
Section: Discussionmentioning
confidence: 99%
“…A recent study compared density measurements from 2 CBCT units (including the CBCT used in our case) and a standard spiral CT, using Urografin ® . 3 There was good correlation between measured density values and iodine concentration, with a linear relationship, for all 3 devices, although there was a significant difference in measurements between the 3 systems for the same iodine concentration. There was also a wider standard deviation in CBCT-derived values when compared with conventional medical grade CT.…”
Section: Discussionmentioning
confidence: 74%
“…The CBCT slopes of the attenuation plots from the CBCT used in this study were nearly linear compared to the other CBCT tested and it appears that linearity between this CBCT and MDCT plots remain stable with increasing density of the imaged material. 3 In another study evaluating bone density of human mandibles, there was also a good linear correlation between values obtained with the 2 technologies, although the measured densities were always greater with CBCT than with conventional CT. 15 CBCT may appear to be adequate to monitor density variations of mineralized structures with time, even though the values may not be as accurate as with conventional CT. However comparison of gray scale values of CBCT and CT in an in vitro study on dried mandible didn’t reach the same conclusion and stated that determination of gray values in CBCT may not be as accurate as HU value in CT for hyperdense structures.…”
Section: Discussionmentioning
confidence: 86%
See 1 more Smart Citation
“…The use of density values calculated from CBCT scans has been previously validated as a reliable assessment of bone density, although the actual values may not be the same as those obtained through computed tomography, because of differences in the measurement technology. 37…”
Section: Discussionmentioning
confidence: 99%