2016
DOI: 10.1017/s1431927616000106
|View full text |Cite
|
Sign up to set email alerts
|

Density Functional Theory Modeling of Low-Loss Electron Energy-Loss Spectroscopy in Wurtzite III-Nitride Ternary Alloys

Abstract: In the present work, the dielectric response of III-nitride semiconductors is studied using density functional theory (DFT) band structure calculations. The aim of this study is to improve our understanding of the features in the low-loss electron energy-loss spectra of ternary alloys, but the results are also relevant to optical and UV spectroscopy results. In addition, the dependence of the most remarkable features with composition is tested, i.e. applying Vegard's law to band gap and plasmon energy. For thi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 38 publications
0
5
0
Order By: Relevance
“…E p follows an approximately linear dependence with respect to the alloys’ compositional as observed experimentally In x Al 1−x N17 and calibrated according to calibrated according19, although to fully account for dependence, the usage of bowing parameter was suggested2728. VEELS SIs were recorded using a probe convergence semi-angle of 20 mrad, which delivered sub-Ångström resolution with 0.3 nA current, 0.025 eV/channel energy dispersion, a collection semi-angle of 12 mrad and 0.005 s dwell time for each pixel.…”
Section: Methodsmentioning
confidence: 96%
“…E p follows an approximately linear dependence with respect to the alloys’ compositional as observed experimentally In x Al 1−x N17 and calibrated according to calibrated according19, although to fully account for dependence, the usage of bowing parameter was suggested2728. VEELS SIs were recorded using a probe convergence semi-angle of 20 mrad, which delivered sub-Ångström resolution with 0.3 nA current, 0.025 eV/channel energy dispersion, a collection semi-angle of 12 mrad and 0.005 s dwell time for each pixel.…”
Section: Methodsmentioning
confidence: 96%
“…From the CDF the ELF can be directly obtained. Figure 5 shows the ELF compared with the experimental low loss spectra [40]. The difference in relative intensity on the imaginary CDF caused form 2 to have broader peaks for low losses of energy.…”
Section: Resultsmentioning
confidence: 99%
“…Modified Becke–Johnson (mBJ) exchange potential was considered for the high symmetry ordered case. The relaxed structure was used to compute the energy loss function (ELF) and the complex dielectric function (CDF) by OPTIC task of WIEN2k package. , The Perdew–Burke–Ernzerhof (PBE) functional was used setting RKmax to 7.0 and defining 500 k-points on the Brillouin zone. The energy and charge convergence criterion were set to 0.0001 Ry and 0.001 e, respectively.…”
Section: Methodsmentioning
confidence: 99%