Delivering RapidArc®: A comprehensive study on accuracy and long term stability

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
15
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(16 citation statements)
references
References 32 publications
(74 reference statements)
1
15
0
Order By: Relevance
“…[2][3][4] VMAT's advantages can be realized if a comprehensive commissioning and quality assurance (QA) program are routinely implemented. 5 Previous studies 6,7 have proposed a set of tests that are specific to the implementation of Varian RapidArc (Varian Medical Systems, Palo Alto, CA, USA). However, due to difficulties related to film dosimetry and portal images, the delivery aspects of VMAT could not be assessed separately and with sufficient gantry-angle resolution.…”
Section: Introductionmentioning
confidence: 99%
“…[2][3][4] VMAT's advantages can be realized if a comprehensive commissioning and quality assurance (QA) program are routinely implemented. 5 Previous studies 6,7 have proposed a set of tests that are specific to the implementation of Varian RapidArc (Varian Medical Systems, Palo Alto, CA, USA). However, due to difficulties related to film dosimetry and portal images, the delivery aspects of VMAT could not be assessed separately and with sufficient gantry-angle resolution.…”
Section: Introductionmentioning
confidence: 99%
“…Scaggion et al reported that the mean mechanical errors in clinical VMAT plans were less than 1 mm, 0.5°, and 0.1 MU for MLC position, gantry angle, and MU, respectively, during RapidArc treatments delivered with a 6 MV UNIQUE linac (Varian Medical Systems, Palo Alto, CA, USA) over 2 years [ 9 ]. José Olasolo-Alonso et al also reported that the average RMSE values of the MLC were 0.3 mm for Clinac linac (Varian Medical Systems) in intensity-modulated radiation therapy (IMRT) treatments, and 0.04 mm for TrueBeam linacs (Varian Medical Systems) in VMAT treatments, according to 3000 logfiles obtained from four institutions [ 10 ].…”
Section: Discussionmentioning
confidence: 99%
“…Even if the dosimetric QA testing results meet institutional criteria, there is no guarantee that treatment machines will continue to perform correctly throughout the course of treatment. Several studies have reported that daily machine errors were small throughout the course of VMAT treatment [ 9 , 10 ]; however, it is generally difficult to predict dosimetric impacts on patient anatomy due to mechanical errors. Thus far, no studies have reported monitoring of the dosimetric impact of mechanical errors throughout the course of treatment.…”
Section: Introductionmentioning
confidence: 99%
“…In this work, we also tried to analyze MLC speed properties because it is an important VMAT plan parameter and it has direct relation to beam to the scale of beam modulation and deliverability [6,[14][15][16][17]28]. Thus, VMAT plans can be characterized by MLC speed.…”
Section: ) Mlc Speed Errormentioning
confidence: 99%