2019
DOI: 10.14407/jrpr.2019.44.1.32
|View full text |Cite
|
Sign up to set email alerts
|

Plan-Class Specific Reference Quality Assurance for Volumetric Modulated Arc Therapy

Abstract: Background: There have been much efforts to develop the proper and realistic machine Quality Assurance (QA) reflecting on real Volumetric Modulated Arc Therapy (VMAT) plan. In this work we propose and test a special VMAT plan of plan-class specific (pcsr) QA, as a machine QA so that it might be a good solution to supplement weak point of present machine QA to make it more realistic for VMAT treatment. Materials and Methods: We divided human body into 5 treatment sites: brain, head and neck, chest, abdomen, and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 27 publications
(34 reference statements)
0
1
0
Order By: Relevance
“…Because there is no golden reference methodology to correctly predict VMAT delivery accuracy, even an ideal indicator cannot always show strong correlations to every conventional measure of VMAT delivery accuracy. Although the planar gamma-index method has been widely adopted in clinical settings since being suggested by Low et al [13], its limitations have been raised in several studies, and include the clinical irrelevance of gamma passing rates, the high dependency of gamma passing rates on dosimeter type, no clear gamma criterion with tolerance levels, a lack of information of 2D dose distributions, and dosimeter setup error dependency [11, 16, 2732]. Machine log file analysis also is limited by its dependency on the linac control system.…”
Section: Discussionmentioning
confidence: 99%
“…Because there is no golden reference methodology to correctly predict VMAT delivery accuracy, even an ideal indicator cannot always show strong correlations to every conventional measure of VMAT delivery accuracy. Although the planar gamma-index method has been widely adopted in clinical settings since being suggested by Low et al [13], its limitations have been raised in several studies, and include the clinical irrelevance of gamma passing rates, the high dependency of gamma passing rates on dosimeter type, no clear gamma criterion with tolerance levels, a lack of information of 2D dose distributions, and dosimeter setup error dependency [11, 16, 2732]. Machine log file analysis also is limited by its dependency on the linac control system.…”
Section: Discussionmentioning
confidence: 99%