2011
DOI: 10.1007/s00706-011-0504-8
|View full text |Cite
|
Sign up to set email alerts
|

Degradation of atrazine by Fenton and modified Fenton reactions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
14
0
2

Year Published

2012
2012
2018
2018

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(19 citation statements)
references
References 31 publications
2
14
0
2
Order By: Relevance
“…A Fenton-like system using cobaltperoximonosulfate was effective to remove atra-zine under solar irradiation (Bandala et al, 2007). Fenton and the Fenton-like system Fe 0 /H2O2/H2SO4 were also effective on the removal of this herbicide, leading to toxicologically inactive small organic mole-cules or even to mineralization (Mackul'ak et al, 2011). Table S2 describes some electro-Fenton-based processes applied to the degradation of PFOS and some pesticides listed in the priority sub-stances of the Directive 2013/39/EU, namely the triazine pesticide atra-zine, the phenylurea pesticide diuron and the organophosphorus pentachlorophenol, all of them tested at mg L −1 levels.…”
Section: Photo-fenton and Photo-fenton Like Processesmentioning
confidence: 99%
See 1 more Smart Citation
“…A Fenton-like system using cobaltperoximonosulfate was effective to remove atra-zine under solar irradiation (Bandala et al, 2007). Fenton and the Fenton-like system Fe 0 /H2O2/H2SO4 were also effective on the removal of this herbicide, leading to toxicologically inactive small organic mole-cules or even to mineralization (Mackul'ak et al, 2011). Table S2 describes some electro-Fenton-based processes applied to the degradation of PFOS and some pesticides listed in the priority sub-stances of the Directive 2013/39/EU, namely the triazine pesticide atra-zine, the phenylurea pesticide diuron and the organophosphorus pentachlorophenol, all of them tested at mg L −1 levels.…”
Section: Photo-fenton and Photo-fenton Like Processesmentioning
confidence: 99%
“…3). Although atrazine has been banned in the European Union due to the widespread contamination of drinking water supplies, this pesticide considered an EDC, is still used in other regions of the world and for this reason is widely studied (Mackul'ak et al, 2011). Table S1 shows that atrazine was poorly degraded with UV/H2O2 using pre-treated water spiked with a set of 15 compounds at 10 μg L −1 each, while the conversion of all other tested compounds was higher (LekkerkerkerTeunissen et al, 2013).…”
Section: Pesticidesmentioning
confidence: 99%
“…Fenton reaction treatment of atrazine resulted in its total degradation, forming oxalic acid, urea, formic acid, acetic acid, and acetone, identified as stable final small molecules (Mackul'ak et al, 2011).…”
Section: Fenton Reactionmentioning
confidence: 99%
“…47 50 A aplicação de processos Fenton na remoção de herbicidas e outras substâncias usadas no controle de pragas ambientais já foi amplamente relatada na literatura. [51][52][53][54] No caso dos herbicidas, a maior ocorrência e acumulação se dão em solos, pois estas substâncias são altamente lipofílicas. No entanto, a lixiviação do solo por água de chuva, marés, ou ainda, mudança no leito de rios, pode provocar o arraste dos herbicidas para os compartimentos aquáticos, o que levaria à contaminação dos mesmos e a necessidade de remoção dos herbicidas de ambientes aquáticos.…”
Section: Vantagens E Limitações Dos Processos Fentonunclassified