Decentralized Fast Delayed Signal Cancelation Secondary Control for Low Voltage Ride-Through Application in Grid Supporting Grid Feeding Microgrid

Abstract: In this study, a distributed secondary control is proposed alongside the conventional primary control to form a hierarchical control scheme for the Low Voltage Ride-Through (LVRT) control and applications in the inverter-based microgrid. The secondary control utilizes a fast Delayed Signal Cancelation (DSC) algorithm for the secondary control loop to control the reactive and active power reference by controlling the sequences generated. The microgrid consists of four Distributed Energy Resources (DER) sources … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 31 publications
0
3
0
Order By: Relevance
“…Consequently, the required reactive current injection under fault in the AC grid is guided by the given expression. Once the PCC voltage sequence components are obtained in direct-quadrature coordinates when grid failure occurs using Equation (18), broken down into Equations ( 19) and ( 20), the two PCC voltage-independent control systems restore normal sequence references. Positive sequence control aims to bring the PCC voltage's positive sequence level back to its rated value.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Consequently, the required reactive current injection under fault in the AC grid is guided by the given expression. Once the PCC voltage sequence components are obtained in direct-quadrature coordinates when grid failure occurs using Equation (18), broken down into Equations ( 19) and ( 20), the two PCC voltage-independent control systems restore normal sequence references. Positive sequence control aims to bring the PCC voltage's positive sequence level back to its rated value.…”
Section: Resultsmentioning
confidence: 99%
“…Aside from FRT, future inverter-based microgrid systems are expected to integrate grid support, grid fault resistance, dynamic power regulation, and smart ancillary service supply at the PCC [17,18]. Additionally, as soon as the grid voltage recovers or the fault is cleared, the PV system is required to function at its maximum active power point for a set time at a power factor of unity.…”
Section: Introductionmentioning
confidence: 99%
“…The Pω droop control adjusts the active power output of the inverter based on the deviation between the actual grid frequency (ω) and the reference frequency. By incorporating this droop control, the inverter actively contributes to regulating the grid frequency, maintaining it within the desired range [18].…”
Section: Grid Supporting Controlmentioning