2022
DOI: 10.1016/j.buildenv.2022.108819
|View full text |Cite
|
Sign up to set email alerts
|

Decay rates of two tracer gases compared to DNA-tagged liquid aerosol tracer particles: Impact of varying dilution rate and filtration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 11 publications
(14 citation statements)
references
References 21 publications
0
12
0
Order By: Relevance
“…The DNA tracer solution is emitted using a pneumatic nebulizer with a known volumetric emission rate. 11 Volumetric particle size distributions upon emission were measured in triplicate 0.15 m from the nebulizer with a Spraytec laser diffraction particle counter (0.12−1000 μm, Malvern Panalytical Ltd.) and converted to normalized particle number concentrations. The average relative particle number distribu-tion of the nebulizer is compared to a normalized distribution from the BLO trimodal model of cough aerosols in Figure S1.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…The DNA tracer solution is emitted using a pneumatic nebulizer with a known volumetric emission rate. 11 Volumetric particle size distributions upon emission were measured in triplicate 0.15 m from the nebulizer with a Spraytec laser diffraction particle counter (0.12−1000 μm, Malvern Panalytical Ltd.) and converted to normalized particle number concentrations. The average relative particle number distribu-tion of the nebulizer is compared to a normalized distribution from the BLO trimodal model of cough aerosols in Figure S1.…”
Section: Methodsmentioning
confidence: 99%
“…Aerosolized DNA Tracer Removal Rate. Measuring bulk aerosolized DNA tracer removal rates (λ trc,meas ) in buildings, which accounts for the combined removal rates of ventilation, filtration, and deposition, can be accomplished using aerosolized tracer concentration decay techniques, 11 and we assume bulk aerosolized tracer removal rates are equivalent to bulk respiratory aerosol removal rates due to similarities in particle size distributions and composition. When aerosol tracer decay rates cannot be measured, gaseous tracer removal rates (λ gas ) or ventilation rates (q v /v r ) can be used to estimate tracer aerosol removal rates using the linear regression described in Section S6.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations