2020
DOI: 10.1016/j.dib.2019.104917
|View full text |Cite
|
Sign up to set email alerts
|

Data from calorimetric decay heat measurements of five used PWR 17x17 nuclear fuel assemblies

Abstract: Raw data from calorimetric measurements of five nuclear fuel assemblies of the PWR 17 × 17 type are provided. Measurements of the temperature both inside a calorimeter, in which the fuel assembly was placed, as well as outside, were performed as a function of time while water circulating inside the calorimeter heats up from radiation emitted in the radioactive decay of material in the fuel assembly. The data contain also measurements of dose rate in the water outside the calorimeter. Data from 38 measurements … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(1 citation statement)
references
References 0 publications
0
1
0
Order By: Relevance
“…(**) indicates that the fuel assembly was reconstructed after discharge from the reactor. Fuel assemblies identified by BWRnn, PWRnn and BTnn are the same as those measured in references [1] , [2] , [3] , respectively. Id Fuel type BU [GWd/tU] IE [%] Loading date Discharge date # Cycles BT01 17 × 17 PWR Fuel Type 6 52.68 3.95 1993–09–27 1997–08–21 4 BT02 17 × 17 PWR Fuel Type 1 55.09 3.95 2010–06–30 2014–08–06 4 BT03 17 × 17 PWR Fuel Type 1 50.29 3.95 2005–08–31 2010–06–17 4 BT04 17 × 17 PWR Fuel Type 1 50.76 3.7 2005–08–31 2009–04–30 4 BT05 17 × 17 PWR Fuel Type 1 50.25 3.6 1994–10–09 2005–08–04 4 BWR02 10 × 10 BWR Fuel Type 2 43.76 3.2 1999–06–09 2004–08–17 5 BWR03 10 × 10 BWR Fuel Type 2 44.36 3.396 1996–08–18 2002–08–12 9 BWR05 10 × 10 BWR Fuel Type 1 42.02 3.14 1999–10–28 2006–08–29 7 BWR06 8 × 8 BWR Fuel Type 1 38.15 2.665 1978–08–05 1985–09–12 9 BWR07 10 × 10 BWR Fuel Type 2 41.24 3.144 1999–06–09 2004–08–17 5 BWR10 10 × 10 BWR Fuel Type 1 39.5 3.14 2001–08–29 ...…”
Section: Data Descriptionmentioning
confidence: 99%
“…(**) indicates that the fuel assembly was reconstructed after discharge from the reactor. Fuel assemblies identified by BWRnn, PWRnn and BTnn are the same as those measured in references [1] , [2] , [3] , respectively. Id Fuel type BU [GWd/tU] IE [%] Loading date Discharge date # Cycles BT01 17 × 17 PWR Fuel Type 6 52.68 3.95 1993–09–27 1997–08–21 4 BT02 17 × 17 PWR Fuel Type 1 55.09 3.95 2010–06–30 2014–08–06 4 BT03 17 × 17 PWR Fuel Type 1 50.29 3.95 2005–08–31 2010–06–17 4 BT04 17 × 17 PWR Fuel Type 1 50.76 3.7 2005–08–31 2009–04–30 4 BT05 17 × 17 PWR Fuel Type 1 50.25 3.6 1994–10–09 2005–08–04 4 BWR02 10 × 10 BWR Fuel Type 2 43.76 3.2 1999–06–09 2004–08–17 5 BWR03 10 × 10 BWR Fuel Type 2 44.36 3.396 1996–08–18 2002–08–12 9 BWR05 10 × 10 BWR Fuel Type 1 42.02 3.14 1999–10–28 2006–08–29 7 BWR06 8 × 8 BWR Fuel Type 1 38.15 2.665 1978–08–05 1985–09–12 9 BWR07 10 × 10 BWR Fuel Type 2 41.24 3.144 1999–06–09 2004–08–17 5 BWR10 10 × 10 BWR Fuel Type 1 39.5 3.14 2001–08–29 ...…”
Section: Data Descriptionmentioning
confidence: 99%