2013
DOI: 10.1016/j.desal.2013.02.006
|View full text |Cite
|
Sign up to set email alerts
|

Data-driven models of steady state and transient operations of spiral-wound RO plant

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
13
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 29 publications
1
13
0
Order By: Relevance
“…It has been shown that irreversible resistance arises in the short and initial period of the process. The efficiency is determined by reversible resistance, confirmed by the literature [ 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 ]. The values of individual resistances are much higher, relating to the values in other membrane processes.…”
Section: Resultssupporting
confidence: 65%
See 1 more Smart Citation
“…It has been shown that irreversible resistance arises in the short and initial period of the process. The efficiency is determined by reversible resistance, confirmed by the literature [ 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 ]. The values of individual resistances are much higher, relating to the values in other membrane processes.…”
Section: Resultssupporting
confidence: 65%
“…The values of individual resistances are much higher, relating to the values in other membrane processes. It is related to the more significant pressure difference occurring on both sides of the membrane, which is characteristic of this process [ 6 , 9 , 13 , 26 , 27 , 32 ]. Based on the research, it was found that the value of irreversible resistance increases over time and is much greater than the reversible resistance.…”
Section: Resultsmentioning
confidence: 99%
“…Instead, for the lowest filtration duration (20 min), all the conditions tested for the concentration of 97 mgNPs L −1 are viable as well as the two lowest pressure for the concentration of 251 mgNPs L −1 . Moreover, simulation of dead-end filtration mode indicated that only one suspension (97 mgNPs L −1 ) presents noticed characteristics about the filtration duration for TMP between 0.2 to 0.4 bar, and this respecting filtration times mentioned in the literature (20-60 min) (Cordier et al, 2018;Payant, 2016). Overall, results of this study clearly indicate that dead-end filtration is not suitable for CMP effluents whose concentration exceeds 100 mgNPs L −1 .…”
Section: Dead-end Model Simulationmentioning
confidence: 64%
“…However, the BW duration can influence the number of filtration cycles, as already observed by Akhondi et al (2014), who indicated that the net permeate volume increases to a maximum value with increasing the BW duration up to 2 min. Finally, Payant (2016) and Cordier et al (2018) mentioned that UF membranes are frequently physically washed every 20-60 min with a BW duration of 1-2 min. It is also mentioned that after each filtration/backwash cycle the membrane does not recover 100% of its initial permeability, but rather 90-97% (Payant, 2016;Remize et al, 2010), due to the irreversible fouling.…”
Section: Uf Units Modellingmentioning
confidence: 99%
See 1 more Smart Citation